XpressFill XF2100 Скачать руководство пользователя страница 1

XpressFill

XF4100 / XF2100

Содержание XF2100

Страница 1: ...XpressFill XF4100 XF2100 ...

Страница 2: ......

Страница 3: ...or death Do not use the machine in any way not covered in this manual or for any purpose other than those explained in the following pages Severe product damage and or injury could result from the use of unqualified Service Technicians or non original replacement parts All repairs must be performed by a qualified Service Technician or with the approval from an XpressFill Technician Only original f...

Страница 4: ...Safety Warnings ...

Страница 5: ... Guarantee We guarantee our products to be free of defects in materials and workmanship The filler will be repaired or replaced if upon inspection at the factory the filler is found to be defective in materials or workmanship This guarantee does not apply to damage resulting from normal wear and tear accident abuse negligence or shipping The guarantee may be rendered invalid if the customer has ma...

Страница 6: ...ses the filler can be cleaned by the customer 265 Prado Road Suite 1 San Luis Obispo CA 93401 805 541 0100 xpressfill com sales xpressfill com 6 XpressFill Systems LLC Unscrew the adjustable knobs holding the shelf to the machine Plug the shelf s electrical connector into the side of the filler shown with optional gas sparge above the shelf connector Unpack the filler from the box Place is on a fl...

Страница 7: ...gas option The green light will take a few seconds to illuminate as the purge cycles operates without gas connected While holding the shelf loosen the adjustable knobs on either side so the shelf moves freely Slowly raise the shelf until the green light goes off Once that light goes off you know you have found the height to set the shelf for bottling Note which holes on the side of the machine are...

Страница 8: ...here is minimal air in the flow path turn the inline strainer upside down while the pump is running with four bottles in place This ensures that the air bubbles in the strainer housing mostly dissolve although a little air bubble in the strainer is normal You are now ready to begin filling Place an empty bottle under each spout Turn on the Pump Switch The filling process will start and stop automa...

Страница 9: ...ycle Variable Flow Control The four white valves on top of your unit are for flow control Each valve controls the spout in which it is aligned The valves functions are to increase or decrease flow per spout Usually if foaming is occurring in your product decreasing flow and or slowing down your flow will eliminate this problem To Decrease flow Turn the knob Clockwise until desired flow is achieved...

Страница 10: ...e does not start it is typically a case of moisture between the spout and sensor tube This can corrected by drying the entire area with a dry cloth or towel in between the two stainless steel sprouts as well as the nylon spacer holding them in place If the problem persists please contact XpressFill for assistance 265 Prado Road Suite 1 San Luis Obispo CA 93401 805 541 0100 xpressfill com sales xpr...

Страница 11: ...es When using PBW in food processing areas the equipment that has been cleaned must be rinsed with potable water After cleaning with PBW the manufacturer recommends sanitizing prior to the next use Saniclean also from Five Star Chemicals is highly effective and completely food grade if diluted correctly per the manufacturer s instructions Use 1 once of the sanitizer in 3 gallons of water and follo...

Страница 12: ...itting and pulling lightly to check that the connection is secure Removal requires using the collet release tool to firmly push the collet and remove the tube A tool is included with the filler and can be found inside the filler 265 Prado Road Suite 1 San Luis Obispo CA 93401 805 541 0100 xpressfill com sales xpressfill com 12 XpressFill Systems LLC Push collet in with tool to remove hosing ...

Страница 13: ...ng filling Spares are offered and located inside the filler Spare Fuse There is a spare fuse in the power cord receptacle Unplug the machine and set a screwdriver on the notch do not remove screws and pop the spare fuse holder toward you then replace the fuse XpressFill Part No 200002 Bussmann Series by Eaton Model BK GDB 2A 250V Fast Acting 5mm x 20mm The exposed fuse in the clip is the active fu...

Страница 14: ...il assembly Remove the coil assembly off the center shaft Unscrew the shaft from the stainless steel base It is not necessary to unscrew the tubing adaptors from the stainless steel base Now rinse out all the openings inside and outside of the solenoid valve removing any particulates and stickiness that may have accumulated Reassemble and replace in the filler Stainless steel valve body is marked ...

Страница 15: ...265 Prado Road Suite 1 San Luis Obispo CA 93401 805 541 0100 xpressfill com sales xpressfill com 15 XpressFill Systems LLC Delay Timer Adjustment Accessory Kit ...