xpr WS4-1D-E Скачать руководство пользователя страница 1

www.xprgroup.com

1

EN

ON

1

2

OFF

WS4-1D-E

1 Door access control unit with web access

DESCRIPTION

SPECIFICATIONS

FACTORY RESET

CHANGE PASSWORD

SOFTWARE SETTINGS

METHOD 1

ADDING READERS

METHOD 2 

ADDING USERS

ADDING SLAVE CONTROLLERS

FIRST CONNECTION AND CONFIGURATION

If you can not connect, it is because your network does not recognize the name of the

WS4-2D-E controller. In this case, go to our web site http://www.xprgroup.com/products/

ws4/ and download the tool called “Device Finder”.

The “Device Finder” will enable you to find out the IP address of the WS4-1D-E controller.

Run the “Device Finder” and you will get a list of all the WS4 controllers connected in

your network, including their IP addresses, just like the picture below.

To add 

2 readers on 1 Door

, select the reader (fig.2) and there, for “Type of Access”

select “Access with 2 readers” (fig 5). Fill the form for both readers and they will

merge in one door (fig. 6)

WS4 system can manage up to 10 WS4 boards in the same installation (with up to 20

doors, whether single or double). One WS4-1D-E must be master, the others must be

slaves. The 

master/slave

 selection is made with 

Dip-switch 2

: OFF - Master (factory

setting), ON - Slave.

Go to “Doors” and click on the link “Add slave”(fig.1). Enter the serial number of the

WS4-1D-E to be added and click Search. If it finds it, the system directly adds this slave

into the installation and you can configure its doors (fig.2).

In case of error, a message is displayed in red.

Go to 

Users

 (fig.1), select “

New

”(fig.2) and then fill the form (Name, category, card

number...)(fig.3).

Open a browser and type the IP of the WS4-1D-E controller and you will be prompted to 

the login page.

User Name: 

admin

Password: 

WS4

 followed by 

Dash

 and the 

Serial Number

 (ex. 

WS4-110034

) just like the

image below, all in capital letters without space.

QUICK USER GUIDE

• Capacity:  

 

 

2500 Users

• Events:  

 

 

50000 max.

• Doors:  

 

 

1 (max. 20 doors in same network)

• Readers: 

 

  2

• Door contact inputs:    

1

• Push button inputs:  

 

1

• Supply for the readers:   

250 mA each max.

• Supply for the locks:    

600 mA each max.

• Relay characteristics:    

2A/48 VAC/DC

• Processor:  

 

 

ARM A5 - 528 Mhz

• Memory:  

 

 

64 MB Ram DDR2 133 Mhz

• TCP/IP connection:  

 

10/100/1000 Base-T – HTTP or HTTPS

• Operating temperature:  

0 °C to +50 °C

• Humidity:  

 

 

0% to 85% (non-condensing)

• Tamper: 

 

  Yes

• Wiegand readers connection:   Yes, via Wiegand to RS-485 converter - WS4-CNV

• Elevator feature:  

 

Yes, 2 elevators per installation, each - 24 floors

• Interlock, Anti pass back, people counter, presence, system logs, reports in CSV

DIP Switch

pos. 1

1

2

3

The WS4-1D does not have default IP address. By default is set to DHCP. There are 2

methods to connect to and configure WS4-1D-E - LAN and Standalone method.

In this configuration, the network’s DHCP server will assign an IP address to your WS4-1D-E

In this configuration, the WS4-1D-E will assign an IP address to your PC. The PC must be set to obtain IP

address automatically.

(For use in a home or business LAN network)

(For standalone use - without LAN network)

1. Put the DIP switch 1 in position OFF.

2. Connect a cable from your network to the ethernet connector of Ws4-1D-E.

3. Open a web browser and enter http://ws4 followed dash and the serial number of

the WS4-1D-E controller

1.  Put the DIP switch 1 in position ON.

2. Connect a cable from your PC directly to the ethernet connector of WS4-1D-E.

3. Open a web browser and enter the following IP - 192.168.50.100, then put the login

credentials like explained above

DIP Switch 1 allows a complete re-initialization of the system. To do this, 

1. Unplug the TCP/IP network cable (Rj45).

2. Switch this dip switch 

3 times OFF - ON - OFF

 within 

10 seconds

3. Wait until the green COMM LED flashes.

DIP Switch 1 allows to log into the system as an administrator if login or 

password is forgotten.

1. Unplug the TCP/IP network cable (Rj45).

2. Toggle this dip switch

 ON

 for about 

15 seconds

, then back to OFF. The 

system will then allow, for 5 minutes, to connect (from the local network 

only) with the default login and password.

Go to “Doors”, select the reader(fig.2) and then select the type of the reader in the

field ”Card”. (fig.3). While off line, red LED blinks fast and buzzer beeps continuously.

Once communication is established, the red LED and the buzzer stop. Green LED

starts to blink continuously. If you want to stop the green LED, go to Settings/System

Options and select for the backlight ON or OFF (not default) fig.4

v.

c1

fig.1

fig.3

fig.5

fig.1

fig.2

Switch

Master

DIP switch 2

OFF

Slave 1

DIP switch 2

ON

Slave 9

DIP switch 2

ON

fig.3

fig.6

fig.4

fig.2

fig.1

fig.2

WS4-1D-E is a 1 door control unit designed to operate with readers with RS-485 output.

There is no need to install any software. There is no need to have a dedicated PC

either. Everything is available online and the operators just need to register with

controller’s serial number to start using the software application.

Serial number

DIP Switch pos. 1

Factory reset

Change

password

Master/

Slave

DIP switch 2 - ON

NL

DE

ES

IT

FR

EN

Содержание WS4-1D-E

Страница 1: ...installation each 24 floors Interlock Anti pass back people counter presence system logs reports in CSV DIP Switch pos 1 1 2 3 The WS4 1D does not have default IP address By default is set to DHCP The...

Страница 2: ...Gnd for DC and PB 12 VDC for reader RS45 RS 485 B RS45 RS 485 A Gnd for reader Not used For doors equipped with 2 readers one must be at address 0 and the other at address 1 If there is only 1 reader...

Страница 3: ...pports en CSV Le WS4 1D E ne comporte pas d adresse IP par d faut Il est r gl sur DHCP par d faut La connexion et la configuration du WS4 1D E peuvent se faire selon deux m thodes diff rentes LAN et a...

Страница 4: ...rre pour CC et PB 12 VCC pour lecteur RS45 RS 485 B RS45 RS 485 A Terre pour lecteur Non utilis Pour les portes quip es de deux lecteurs l un d entre eux doit se trouver sur l adresse 0 et l autre sur...

Страница 5: ...cco Antiritorno contapersone presenza registri di sistema rapporti in CSV DIP Switch pos 1 1 2 3 Il WS4 1D E non ha un indirizzo IP predefinito impostato su DHCP in maniera predefinita Per collegare e...

Страница 6: ...ta 1 Premere il pulsante 1 GND per DC e PB 12 VDC per lettore RS45 RS 485 B RS45 RS 485 A GND per lettore Non usato Per le porte provviste di 2 lettori una deve essere indirizzata su 0 e l altra su 1...

Страница 7: ...gistros del sistema informes en CSV DIP Switch pos 1 1 2 3 La WS4 1D E no tiene una direcci n IP predeterminada sino que est establecido en DHCP Existen 2 m todos para conectar y configurar la WS4 1D...

Страница 8: ...ontactos 12 VDC for reader RS45 RS 485 B RS45 RS 485 A Conexi n a tierra del lector No se utiliza En las puertas equipadas con 2 lectores uno debe estar en la direcci n 0 y el otro en la direcci n 1 S...

Страница 9: ...ersonenz hler Anwesenheit Systemlogs Berichte in CSV DIP Switch pos 1 1 2 3 Der WS4 1D E Controller verf gt nicht ber eine automatisch zugewiesene IP Adresse Die Voreinstellung ist DHCP Es gibt 2 M gl...

Страница 10: ...T rschloss T rkontakt 1 Drucktaster 1 GND f r T rkontakt und Drucktaster 12 VDC f r Leser RS45 RS 485 B RS45 RS 485 A GND f r Leser Nicht zugewiesen Die Leser der T ren 1 0 m ssen die Adresse 0 und d...

Страница 11: ...r installatie elk 24 etages Vergrendeling anti passback personenteller aanwezigheid systeemlogs rapporten in CSV DIP Switch pos 1 1 2 3 De WS4 1D E heeft geen standaard IP adres Deze is standaard inge...

Страница 12: ...op 1 GND voor DC en PB 12 VDC for reader RS45 RS 485 B RS45 RS 485 A GND voor lezer Niet gebruikt Bij deuren met 2 lezers moet n lezer op adres 0 en de andere op adres 1 zijn ingesteld Als er slechts...

Отзывы: