www.xprgroup.com
1
B100PROX-MF V1
Biometric Mifare Reader
EN
USER’S MANUAL
v.
c1
Страница 1: ...www xprgroup com 1 B100PROX MF V1 Biometric Mifare Reader EN USER S MANUAL v c1...
Страница 2: ...ING FINGERPRINTS FROM A READER 8 3 ENROLLING FINGERPRINTS FROM DESKTOP READER 8 4 DELETING FINGERPRINTS 8 5 UPLOADING THE FINGERPRINTS TO THE BIOMETRIC READERS 8 6 FIRMWARE UPDATE 8 7 SEND CONFIGURATI...
Страница 3: ...a Wiegand biometric and proximity reader for access control applications with programmable wiegand output It offers storage of up to 100 fingerprints it reads Mifare Classic 1K 4K Ultralight Desfire...
Страница 4: ...sealed wall mount box fitted with additional heater if very low temperature to keep a constant sensor level performance XPR cannot guarantee the functionality of the product if measures and advice be...
Страница 5: ...established The Biometric readers are connected through RS 485 bus The same RS 485 bus that the EWS controllers are connected to Maximum units in one network EWS Biometric readers is 32 If there are m...
Страница 6: ...built in resistor 120 ohm by closing the jumper If the communication is not established and stable use the external resistors provided in the hardware kit When using CAT 5 compatible cable in most of...
Страница 7: ...stubs from the RS 485 backbone as short as possible not more than 5 meters Only one converter per installation is needed not per reader 6 1 CONVERTERS PIN DESCRIPTION 7 ENROLLMENT CNV200 Converter RS...
Страница 8: ...the type a third tab will appear Biometric Go to that tab and put the serial number of the Biometric Reader 8 3 Important Note The serial number of the reader can be found on a sticker inside the rea...
Страница 9: ...tric Readers where that user has access i e to all the readers according to the Access Level assign to that user Example If the user has Unlimited Access level then the fingerprints will be sent to al...
Страница 10: ...rs where that user has access i e to all the readers according to the Access Level assign to that user Example If the user has Unlimited Access level then the fingerprints will be sent to all readers...
Страница 11: ...Delete one or more fingerprints Select the User and open the Biometric tab Go to the fingertip that needs to be deleted right click and select Delete for one finger or Delete All for all fingers of t...
Страница 12: ...or any communication device in between during the entire process Right click on the reader and select the Send configuration menu See the events panel to check the configuration flow Note The biometri...
Страница 13: ...wiegand number 8 21 Right click on the biometric reader Select Properties and go to the Biometric tab For Entry Mode select Card and Finger 8 21 Use of the double security mode Present the card ex 880...
Страница 14: ...prints is edited or the fingerprints should be saved in the software database click Save otherwise go to another user or close the window if no other user management is required Note Depending on the...
Страница 15: ...configuration 1 to 8 digits and PIN Code transfer Wiegand Output Configuration The Wiegand output of the Biometric reader can be customized bitwise 9 1 ADD PORTAL 9 2 ADD READER Right click on Portal...
Страница 16: ...s added on top of the event table Right click on the reader and select Properties If reader is online right click on reader and select Upload configuration Check at event table if configuration was su...
Страница 17: ...nt automatically to all Biometric Readers where that user has access i e to all the readers according to the Access Level assign to that user Example If the user has Unlimited Access level then the fi...
Страница 18: ...Delete one or more fingerprints Select the User and open the Biometric tab Go to the fingertip that needs to be deleted right click and select Delete for one finger or Delete All for all fingers of t...
Страница 19: ...setup custom Wiegand format Select Wiegand menu from Settings At Wiegand setup window select one from customs Wiegand Set Wiegand parameter Click on Save button Note Wiegand settings are out of scope...
Страница 20: ...SCRIPTION The data is sent over the lines DATA 0 for the logic 0 and DATA 1 for the logic 1 Both lines use inverted logic meaning that a pulse low on DATA 0 indicates a 0 and a pulse low on DATA 1 ind...