xpr B100PROX-EH-SA v2 Скачать руководство пользователя страница 6

6

 ADDING ADMIN FINGER

1.Push dip switch no.2 in position ON.

2.Reset the Power of the device.

3.Wait for One long + multiple short beeps

4.Put the dip switch in position OFF. (short beeps will stop)

5.Wait for about 

15 seconds

 for the LED to blink in Orange.

6.Swipe the Master finger min.6 times. (Until Ok Beep)

No.2

No.2

Warning:

 This procedure also deletes all the users and the installer finger.

Warning:

 This procedure will unpair the connected relay unit (RTT, DINRTT or RU2)

 

x

 

6

ON

1 2

ON

1 2

Tricolor Status LED

 - Access Granted

Green

 - Access denied

Red

 - Idle Mode

Orange

OK Beep

    - short + long beep

 - 3 short beeps

Error Beep

Swipe Finger - 2 short beeps

 INDICATION

Follow the below instructions for correct finger swiping. Starting from the first finger joint, place the 
selected finger on the swipe sensor and move it evenly towards oneself in one steady movement.

Result:
For a valid swipe: Tricolour Status LED turns green + OK Beep(short + long beep)
For an invalid or misread swipe: Tricolour Status LED turns red + Error Beep ( 3 short beeps)

 RECOMMENDED SWIPING TECHNIQUE

12/24V AC/DC

Содержание B100PROX-EH-SA v2

Страница 1: ...B100PROX EH SA v2 B100PROX MF SA v2 Standalone Biometric Reader 1 INSTALLER S MANUAL v c2...

Страница 2: ...is access control ngerprint reader designed for easy management of the users and con guration The scanner is made with advanced capacitive sensing technology that provides some advantages over optical...

Страница 3: ...tly the dirt Do not use chemicals and materials that can scratch the sensor WARNING 3 MOUNTING 100 mm 94 mm 30 mm Cable 6 0 30mm MCD MINI Do not install the device and cabling close to a source of str...

Страница 4: ...ht Desfire B100PROX MF SA 1 x Relay 2A 24V AC DC Yes Pulse 1 to 30 seconds or Toggle ON OFF Finger or Card By swiping 1 Administrator and 1 Installer Finger Yes Yes via converter and windows applicati...

Страница 5: ...ND PB PB _ Blue Yellow Red Black Pink Violet Orange Gray White Green 1N4001 Diode Electric Strike ON 1 2 ON 1 2 Adding Admin Finger CARD Type Dipswitch A Card Type ON HID OFF EM ON 1 2 Dipswitch A Dip...

Страница 6: ...nected relay unit RTT DINRTT or RU2 x6 ON 1 2 ON 1 2 Tricolor Status LED Access Granted Green Access denied Red Idle Mode Orange OK Beep short long beep 3 short beeps Error Beep Swipe Finger 2 short b...

Страница 7: ...connected to remote relay unit at secured area which also can play the role of request to exitpushbutton Followtheinstructionsbellowtopair couple bothdevicesorrefertotheRemoteRelay sManual 12 VDC 1N4...

Страница 8: ...t Buzzer Sound x 2 ADD Finger Relay 2 Finger that will activate remote relay 2 slow blinking fast blinking short beep short long beep short beep Swipe User Finger min 6 times until short long beep x 6...

Страница 9: ...5 x 6 short beep short long beep 3 short beeps Swipe Admin Finger 6 times Action Wait 5 seconds until fast blinking Swipe NEW Installer Finger min 6 times Finger Backlight Buzzer Sound x 6 x 6 CHANGE...

Страница 10: ...ent card tag SWIPE new finger min 6 times or present card tag SWIPE ADMIN finger 2 times to DELETE ALL SWIPE new ADMIN FINGER min 6 times SWIPE new INSTALLER FINGER min 6 times Swipe the ADMIN Finger...

Страница 11: ...Swipe the INSTALLER Finger to stop or wait 30 seconds to put the relay in toggle mode fast blinking short long beep x 1 x 1 Swipe Installer Finger 3 times Action Swipe Installer Finger Finger Backligh...

Страница 12: ...OFF Swipe the Installer Finger to stop or wait 30 seconds to put the relay in toggle ON OFF mode Only in combination with DINRTT and RU2 Swipe the Installer Finger and start counting seconds Swipe the...

Отзывы: