Example of a door with 2 r electric strike fail close 

Door contact

OUT

Address 0

Power supply 14,2V

Push button

Push button

Door contact

Electromagnetic Lock 12V/600mA max

Box Tamper

Network

IN

Address 1

Reader

Address 0

Address 1

12V/600mA max

12V/600mA max

electric 

strike (fail close

Reader

See user manual

A

B

B

B

A

A

www.xprgroup.com

V+

V-

+

-

2

Connection example of 3 doors

1. The readers for Doors 1.0 and 2.0 must be at address 0 and 
those for Doors 1.1 and 2.1 at address 1. 
2. For doors equipped with 2 readers, one must be at address 
0 and the other at address 1.
3. The function of OUT1 and OUT2 can be configured in the 
software
4. In1 & In2: Connect to GND by a volt-free contact to activate 
the input
5. LIYCY cable, twisted pair, up to 80m.
If more than 80 m. are needed, then termination resistors(120 
ohm) may be required at both ends of the RS485 line, while 
taking into consideration the lengths proposed on our web 
site.
6. Alarm cable 2x0,22
7. The cross section of the cable depends on the current 
needed by the lock

Note: The elevators relay boards (WS4-RB-12) are connected 
on the same Rs485 lines as the readers.

4

6

7

5

5

3

3

6

7

6

5

5

7

6

2

2

1

1

12V battery

Example of a door with 1 electric strike fail open 

Example of a door with 1 electromagnetic lock

electric 

strike (fail open

Emergency

button

Alarm siren

or

flash siren

This product herewith complies with requirements of EMC directive 2014/30/EU. 

In addition it complies with RoHS2 directive EN50581:2012