background image

English - 10

Circuit Breaker

If the machine stops working, pressing the 

RESET BUTTON 

to reset the machine.

Power Switch

• Turn to “

O

” position to switch the power OFF. Turn to “

I

” position to switch the power 

ON.

Speed Switch

• Turn to “

OFF

” position to switch the fan OFF. Turn clock-wisely to any position between 

MAX

” and “

MIN

” to switch the fan ON.

• You can adjust to any desired speed variably. “

MAX

” is the highest speed and “

MIN

” is 

the lowest  speed.

Pressure Gauge

This measures the negative pressure between the motor inlet and filter outlet.

• Before the first usage, you should zero the pressure gauge in order to ensure the 

accuracy of the measurement. (

See Page 6: Zero Setting

)

• Load all the filters, switch the power on and turn to the highest speed. If the negative 

pressure exceeds the values below, it indicates that the filters might have exceeded 

the maximum capacity of particles, and the filtration efficiency as well as the airflow 

have diminished. You should check, clean or replace the filters. (

See Page 12: Filter 

Maintenance

)

• Even if the pressure gauge shows negative pressure is still lower than the values 

below, it’s suggested to check and replace the filters every 6 months. (

See Page 12: 

Filter Maintenance

)

AP-1500D Series

AP-1800D Series

AP-2500D Series

Without Carbon Filter

270 Pa.

370 Pa.

340 Pa.

With Carbon Filter

350 Pa.

500 Pa.

500 Pa.

Control Panel (Continued)

Time Meter (For Model AP-1500DM, AP-1800DM and AP-2500DM Only)

• The time meter contains 3 meters. Press the setting button to switch the meters.

• The master meter shows the total running time from the first usage to the current 

moment. The value of the master meter can’t be reset.

• The value of meter 1 and meter 2 can be reset. Press the setting button up to 5 

seconds to reset the value.

• When the fan turns on, the activity indicator will blink. The running time starts to count. 

When the fan is off, the activity indicator will stay illuminated. 

• When the value exceeds 9999.9 hours, it will start over from 0 again.

Содержание AP-1500D Series

Страница 1: ...r Scrubber Owner s Manual Model AP 1500D Series AP 1800D Series AP 2500D Series 115V 60Hz Read and save these instructions Index NA 1 A40 Edition 1 3 Final www xpower com 1 855 855 8868 info xpower co...

Страница 2: ...speed control device DO NOT touch this appliance or the plug with wet hands or while standing in water DO NOT operate the appliance in any pooled water DO NOT use the product in areas where gasoline p...

Страница 3: ...English 3 1 2 7 8 9 10 11 12 13 16 17 18 19 20 21 22 6 23 24 25 26 29 30 31 32 33 34 35 4 5 3 27 28 14 15 Parts Description Machine...

Страница 4: ...9 Handle Cover 20 Handle Tube 21 Housing 22 Air Quality Sensor Cover 23 Air Quality Sensor 24 Power Switch 25 Speed Switch Knob 26 Control Panel 27 Speed Switch Circuit Board 28 Circuit Breaker 29 Air...

Страница 5: ...OWER s unique and highly innovative Air Scrubbers create a fresh and clean environment for various purposes With a special designed powerful motor XPOWER Air Scrubbers are able to provide suction in e...

Страница 6: ...the filter before the first useage The accuracy of the pressure gauge might be affected by transportation Before the first usage you should zero the pressure gauge in order to ensure the accuracy of t...

Страница 7: ...ff the hex screw with a hex screw driver on the inlet grill cover 2 Take out the inlet grill cover 3 Put the screws through the holes on handle and the back of the machine housing 4 Fasten the screws...

Страница 8: ...relative humidity level High humidity level could cause blockage and damage to filters Power Cord The power cord has a length of 25 feet 7 6 meters Select a location where the power cord can reach the...

Страница 9: ...tes Environmental Protection Agency EPA the index light corresponds to different levels of health concern as below Control Panel Circuit Breaker Air Quality Monitor Power Switch Speed Switch Air Quali...

Страница 10: ...tration efficiency as well as the airflow have diminished You should check clean or replace the filters See Page 12 Filter Maintenance Even if the pressure gauge shows negative pressure is still lower...

Страница 11: ...e wheels Push forward to transport with the trolley handle User Maintenance Instructions Frequent maintenance is recommended on this appliance Failure to follow the maintenance instructions may cause...

Страница 12: ...ren Use a damp cloth to wipe the surface of the housing Do not clean the unit with water directly Check if the grille covers are clean Remove dirt or any other objects that could block the air inlet a...

Страница 13: ...ptured by the HEPA filter and cleaning this filter can be hazardous to human health and contaminate the nearby environment You must replace the filter if all the other filters are clean and however th...

Страница 14: ...l regulations Tips On one of the side of each filter there is a label with an arrow showing the airflow direction When placing the filter the side with label should face up The arrow on the label shou...

Страница 15: ...the additional electrical receptacle and press circuit reset button Unit runs but no or very low air movement Air outlet is blocked Remove blockage Filters are fully loaded The filter clean change lig...

Страница 16: ...0 A Rated Airflow 700 CFM 1100 CFM 1800 CFM Speed Control Variable Speeds Cord Length 13 ft 4 0 m 25 ft 7 6 m Unit Dimension L x W x H 49 3 x 55 5 x 91 in 19 4 x 21 9 x 35 8 cm 57 4 x 63 9 x 94 6 in 2...

Страница 17: ...in PF16 Pleated Media Filter 16 x 16 in 0 8 in Medium filtration for fine dust PF19 19 x 19 in 1 4 in PF23 23 x 23 in 1 8 in CF35 Carbon Filter 16 x 16 in 1 4 in Filtration for gases CF35 490 19 x 19...

Страница 18: ...ordant with product instructions stated in Owner s Manual 3 4 Failure to follow the product instructions or lack of necessary maintenance stated in Owner s Manual Before contacting XPOWER please try o...

Страница 19: ...the address provided by XPOWER with the RMA number on the shipping label or the packaging 3 Include all the original parts and components XPOWER will inspect assess and advise the repairs needed and...

Страница 20: ...Read and save these instructions Index NA 1 A40 Edition 1 3 Final www xpower com 1 855 855 8868 info xpower com 668 S 6th Ave City of Industry CA 91746 USA XPOWER Manufacture INC...

Отзывы: