XPOtool CGP Скачать руководство пользователя страница 5

  

https://www.XPOtool.com  

Item 61544 

Page 5

 

The Tool Experts 
 

   

05 2021

-1

 

 

Functions

 

 

 Caution!

 

 

 

This water pump has a water-sprinkling protection feature and should be placed only in a dry 
environment. Never place the water pump or operate it in the rain or in a humid area. 

 

This water pump should not be used with flammable or harmful liquids. 

 

Dry-running of the water pump must be avoided under all circumstances. 

 

This water pump is for processing clean water. The scope of its application includes irrigating 
the garden, water supply to a household, sprinkling in a garden or on farmland. 

 

This  water  pump  may  not  be  exposed  for  longer  periods  of  time  to  impurities,  sand,  stone, 
sticky substances, etc., mixed in with the conveyed media. For the conveyed media may con-
tain chemical corrosive substances, it is necessary to pay special attention to preventing influ-
ence by these on the material of the pump body. It is not permitted to use this water pump to 
convey drinking water. 

 
Caution!

 If this water pump is used in a swimming pool, garden pond or similar pools, the pump must 

be  supplied  through  a  residual  current  device  (RCD)  having  a  rated  residual  operating  current  not 
exceeding  30 mA.  Always  keep  it  in  a  working  state  to  ensure  the  safety  and  reliability  of  the  water 
pump. In addition, the pump should be placed on a stable base to prevent it from falling down. 
 
 

Electrical connection

 

 

General description

 

 

Danger:

 

During  the  installation  of  the  water  pump,  the  power  supply  to  the  water  pump  must  be 

switched off. 
 

Caution:

 

During the installation of the device, it is necessary to keep it under dry and well aired, at an 

ambient  temperature  below  40 

.  Before  use, the  water  pump  should  be  inspected  for  safety  to en-

sure that there is no damage to the power cable or the plug. 
 

Electrical connection

 

 

Danger:

 

The electrician responsible for installation must check to ensure that the electrical connection 

is in accordance with the standard, including the earth terminal. The water pump must be well earthed.  
 
 

Commissioning

 

 
The pump is not a self-priming pump, this means that the suction hose should first of all be fitted with: 
 

 

a non-return valve with filter; this ensures that, after disconnecting the pump, the hose and the 
pump do not run dry. This part of the hose is suspended in the water to be pumped away, 

 

a hose with coupling nut; this end of the hose is attached to the front of the pump, 

 

both accessories should be securely screwed on to the hose using the hose clip supplied. 

 

Before  fastening  the  hose  to  the  pump,  it  is  best  to  fill  it  with  water  first.  After  this  you  can 
screw the three-way tap or anther 1

″ connector to the outlet of the pump; being on the top of 

the pump. 

 

Then  you  should  loosen  the  small  screw  cap  on  top  of  the  pump  housing  and  fill  the  pump 
housing with water through the opening; then re-seal it. 

 

If the pump housing and the hose have both now been filled with water, you can switch on the 
pump using the on/off switch. 

 

The pump now immediately begins to pump water. 

 

If  the  pump  is  subsequently  switched  off  again,  water  remains  in  the  pump  housing  and  the 
hose which means that when the pump is next switched on it will pump water immediately. 

Содержание CGP

Страница 1: ...nstructions and safety information before using for the first time Technical changes reserved Due to further developments illustrations functioning steps and technical data can differ insignificant ly...

Страница 2: ...ontact form https www wiltec de contacts The most recent version of this manual in various languages can be found in our online shop via https www wiltec de docsearch Our postal address is WilTec Wild...

Страница 3: ...lease contact a quali fied technician Do not try to repair it by yourself This pump is not suitable for use with flammable or explosive materials Make sure that the pump cannot run dry This pump is no...

Страница 4: ...ure switch 4 Cable 5 Pump head 1 Motor cover 2 Connection cable 3 Cable 4 Electron switch 5 Pump head 1 Cable 2 Motor cover 3 Handle 4 Pump head 5 Valve cover 1 Motor cover 2 Handle 3 Switch 4 Pump he...

Страница 5: ...pump must be switched off Caution During the installation of the device it is necessary to keep it under dry and well aired at an ambient temperature below 40 Before use the water pump should be insp...

Страница 6: ...th the pump occurs it must be repaired by a qualified technician Cleaning and care Proper and regular care will not only ensure safe use but also elongate the lifetime of this de vice Warning Switch o...

Страница 7: ...ate collection system for these devices The logo on the article or on its packaging points out that this article must not be treated as normal house hold waste but must be disposed to a recycling coll...