– Error in the UVW output of the control
board
– Check the control board or con-
tact a specialist.
Pump is running, but no
water is draining
– Is there water in the pump?
– Are water inlets and outlets blocked by
foreign objects?
– Does the motor run anti-clockwise?
– Pump can be put into operation
after it has been filled with water.
– Check whether there are any
foreign objects at the water inlet
and outlet.
– Change the order of the two UV
phases in the case of counter-
clockwise operation.
Frequency report P61
Fan damaged
Check whether the fan is dam-
aged or contact a specialist.
Message P49 or P0 after
switching on and starting
up the water pump
– Check that motor rotates counter-
clockwise.
– Check if UVW wire is shorted
– Change order of UV wires
when operating counter-clock-
wise.
– Eliminate interruption errors in
the event of a short circuit.
– Contact a specialist.