https://www.XPOtool.com
Item 63037, 63038
Page 4
The Tool Experts
01 2022
-1
Danger!
•
If the pump is connected to a sink or shower, it must not be used for drinking water at the same
time.
•
This pump may only be used in a circuit equipped with a residual current circuit breaker (FI
switch, 30
mA) in accordance with VDE 0100-702 and 0100-738. When used near swimming
ponds, garden ponds, etc., the pump must be installed in a fixed or flood-proof manner and
secured against falling over. The pump must not be operated if there are people or animals in
the water. When setting up the pump, make sure that the electrical connections are earthed.
Technical specifications
Item num-
ber
Power
(W)
Max. pumping head
(m)
Max. flow rate
(
ℓ
⁄
h
)
Max. suction height
(m)
63037
600
38
2800
7
63038
800
3000
Electrical connections
•
Thoroughly inspect the pump, especially its power cord and plug, before setting it up and con-
necting it to make sure that it is undamaged. A defective pump must not be put into operation,
but must first be repaired.
•
Earthing: The power cable is equipped with two earth contacts. The electrical plug connections
and the socket must be earthed.
Notes!
•
Make sure that the voltage and frequency specified on the type plate of the pump correspond
to the existing network.
•
If the plug of the power cord is damaged, the pump is not guaranteed. The cable must be re-
placed by another original cable. If an extension cable is defective, only this must be replaced.
The cross-section of the extension cable used to operate the pump must at least correspond to
that of the power cable of the pump.
Setup and installation
•
Before starting up the pump, attach the suction and pressure lines to the pump. The suction line
sucks water from the pond into the pump through the suction connection on the side. It must
always be completely tight, otherwise the suction will be difficult or impossible.
•
To keep the suction line tight, the plastic screw connections should be sealed with sealing tape
and the steel or copper screw connections with hemp fibre or sealing tape.
•
A non-return valve should be connected to the suction line; otherwise, the pressure through the
suction line would decrease when the pump is switched off, which would lead to the pump un-
controlled and frequent switching on and off, if it is used e.g., for water supply in the household
or to operate an automatic lawn sprinkler. Basically, it is advisable to connect a non-return valve
directly between the side inlet of the pump and the suction line so that the suction line does not
run empty after switching off and does not lose its pressure. Otherwise, the suction line could
be damaged. In addition, a suction valve can be attached at the beginning of the suction line,
but this is not necessary.
•
The pump sucks in water by itself, but must be pre-filled when used for the first time. All models
are filled with water via the filling connection on the housing. To do this, open the screw cap and
fill it with water until no more air escapes from the housing.
•
If air bubbles appear while pre-filling the pump, gently shake the case to make the air bubbles
disappear, and then continue filling. Repeat this several times until pre-fill water level is exactly