background image

 

https://www.XPOtool.com 

 

Item 63037, 63038

 

Page 4

 

The Tool Experts

 

 

  

 

01 2022

-1

 

 Danger!

 

 

If the pump is connected to a sink or shower, it must not be used for drinking water at the same 
time.

 

 

This pump may only be used in a circuit  equipped with a residual current circuit breaker (FI 
switch, 30

 

mA) in accordance with VDE 0100-702 and 0100-738. When used near swimming 

ponds, garden ponds, etc., the pump must be installed in a fixed or flood-proof  manner and 
secured against falling over. The pump must not be operated if there are people or animals in 
the water. When setting up the pump, make sure that the electrical connections are earthed.

 

 
 

Technical specifications

 

 

Item num-

ber

 

Power

 (W)

 

Max. pumping head

 

(m)

 

Max. flow rate

 (

h

)

 

Max. suction height

 

(m)

 

63037

 

600

 

38

 

2800

 

7

 

63038

 

800

 

3000

 

 
 

Electrical connections

 

 

 

Thoroughly inspect the pump, especially its power cord and plug, before setting it up and con-
necting it to make sure that it is undamaged. A defective pump must not be put into operation, 
but must first be repaired.

 

 

Earthing: The power cable is equipped with two earth contacts. The electrical plug connections 
and the socket must be earthed.

 

 

 Notes!

 

 

Make sure that the voltage and frequency specified on the type plate of the pump correspond 
to the existing network.

 

 

If the plug of the power cord is damaged, the pump is not guaranteed. The cable must be re-
placed by another original cable. If an extension cable is defective, only this must be replaced. 
The cross-section of the extension cable used to operate the pump must at least correspond to 
that of the power cable of the pump.

 

 
 

Setup and installation

 

 

 

Before starting up the pump, attach the suction and pressure lines to the pump. The suction line 
sucks water from the pond into the pump through the suction connection on the side. It must 
always be completely tight, otherwise the suction will be difficult or impossible.

 

 

To keep the suction line tight, the plastic screw connections should be sealed with sealing tape 
and the steel or copper screw connections with hemp fibre or sealing tape.

 

 

A non-return valve should be connected to the suction line; otherwise, the pressure through the 
suction line would decrease when the pump is switched off, which would lead to the pump un-
controlled and frequent switching on and off, if it is used e.g., for water supply in the household 
or to operate an automatic lawn sprinkler. Basically, it is advisable to connect a non-return valve 
directly between the side inlet of the pump and the suction line so that the suction line does not 
run empty after switching off and does not lose its pressure. Otherwise, the suction line could 
be damaged. In addition, a suction valve can be attached at the beginning of the suction line, 
but this is not necessary.

 

 

The pump sucks in water by itself, but must be pre-filled when used for the first time. All models 
are filled with water via the filling connection on the housing. To do this, open the screw cap and 
fill it with water until no more air escapes from the housing.

 

 

If air bubbles appear while pre-filling the pump, gently shake the case to make the air bubbles 
disappear, and then continue filling. Repeat this several times until pre-fill water level is exactly 

Содержание 63037

Страница 1: ...instructions and safety information before using for the first time Technical changes reserved Due to further developments illustrations functioning steps and technical data can differ insignificantl...

Страница 2: ...our contact form https www wiltec de contacts The most recent version of this manual in various languages can be found in our online shop via https www wiltec de docsearch Our postal address is WilTe...

Страница 3: ...Make sure that the pump cannot run dry This pump is not suitable for continuous operation e g cyclical operation of swimming pond filters or in industrial devices This pump is only suitable for pumpi...

Страница 4: ...ate the pump must at least correspond to that of the power cable of the pump Setup and installation Before starting up the pump attach the suction and pressure lines to the pump The suction line sucks...

Страница 5: ...from being dam aged by penetrating clay sludge or other abrasive substances from the pumped liquid No filter may be installed in the pressure line Pressure line The water is pumped from the pump to t...

Страница 6: ...ng in specified waiting time Fill entire suction line with water and check again after 7 min Suction height too high Reduce suction height max 7 m Bottom valve malfunction Check water level of source...

Страница 7: ...ontainer Supply compressed air through appropriate valve until 1 5 bar is reached Pump does not reach required pressure domestic water sup ply Pressure set too low on the pres sure switch Call special...

Страница 8: ...ump housing 28 Motor housing 7 O ring 29 Screw 8 Jet pipe 30 Cable gland 9 Diffuser 31 Cable and plug 10 Impeller 32 Clamp 11 Mechanical seal 33 Screw 12 O ring 34 Capacitor holder 13 Seal holder 35 C...

Страница 9: ...Item 63037 63038 Page 9 The Tool Experts 01 2022 1 Name Name 1 O ring 7 Fill plug 2 High pressure hose 8 Pressure gauge 3 Cable 9 Pressure tank 4 Mechanical pressure switch 10 Screw 5 Cable and plug 1...

Страница 10: ...a separate col lection system for these appliances The logo on the article or on its packaging points out that this article must not be treated as normal house hold waste but must be disposed to a rec...

Отзывы: