background image

 

https://www.XPOtool.com 

 

Item 62975

 

Page 6

 

The Tool Experts

 

 

  

 

01 2022

-1

 

 

Maintenance

 

 

 

Regular maintenance is particularly important for the device to always work perfectly and to be 
used as long as possible.

 

 

Unplug the device from the socket before performing any maintenance or cleaning work.

 

 

Do not structurally change the electrical system of the device. Never perform any maintenance 
work when the motor of the machine is still running. If necessary, contact a professional.

 

 

Be careful of the grinding disc and other moving parts when performing maintenance.

 

 

Before each use of the device, the following must be checked:

 

 

 

the condition of the power cord and plug,

 

 

the sharpness and balance of the grinding disc,

 

 

the correct fixation of the device to the workbench and the tightness of screws and bolts.

 

 
 

Replacing the disc

 

 

 

If worn (beyond a limit of 30

 

mm) or running unbalanced, the grinding disc must be replaced. 

Only use grinding discs with a diameter of 100

 

mm that can withstand high speeds even if they 

are blunt.

 

 

To replace the grinding disc, proceed as follows:

 

 

1.

 

Pull out the plug.

 

2.

 

Use the 13

 

mm wrench to loosen the M8×100 bolts (see Fig.

 

1) so that the entire device can be 

removed from the workbench (see Fig.

 

2).

 

3.

 

Remove the safety cover (see Fig.

 

3).

 

4.

 

Insert the locking pin into the opening in the bottom of the device as shown in Fig.

 

4 to lock the 

spindle. Then loosen the locking pin of the cover using the 13

 

mm wrench (Fig.

 

5).

 

5.

 

Now insert the new disc and then place the upper flange on the spindle (Fig.

 

5). As shown in 

Fig.

 

4, the spindle must be locked with the locking pin. You can tighten the nut with the wrench.

 

6.

 

Replace the cover and tighten the M4×10 screws.

 

7.

 

After you have completed this work, the device must now be attached to the workbench again. 
Re-tighten the M8×100 screws that you have inserted into the connection hole. Use the supplied 
wrench to help.

 

 
 

 

Содержание 62975

Страница 1: ...instructions and safety information before using for the first time Technical changes reserved Due to further developments illustrations functioning steps and technical data can differ insignificantl...

Страница 2: ...r contact form https www wiltec de contacts The most recent version of this manual in various languages can be found in our online shop via https www wiltec de docsearch Our postal address is WilTec W...

Страница 3: ...wellery as they can get caught in moving parts It is recommended to wear non conductive protective clothing and non slip shoes when working Wear a hairnet to protect long hair Use eye and ear protecti...

Страница 4: ...e operator and bystanders 3 The disc diameter must not deviate more than 15 mm from the normal radius Discs with a di ameter of less than 70 mm must not be used under any circumstances 4 The disc must...

Страница 5: ...g the tooth angle also increases the breakability This can increase the risk of the chain breaking 3 Bring the chain level with the grinding disc Use the setting key for this Fig 8 4 Tighten the chain...

Страница 6: ...limit of 30 mm or running unbalanced the grinding disc must be replaced Only use grinding discs with a diameter of 100 mm that can withstand high speeds even if they are blunt To replace the grinding...

Страница 7: ...https www XPOtool com Item 62975 Page 7 The Tool Experts 01 2022 1...

Страница 8: ...eparate col lection system for these appliances The logo on the article or on its packaging points out that this article must not be treated as normal house hold waste but must be disposed to a recycl...

Отзывы: