Troubleshooting
Problem
Cause
Solution
Pump does not start
No power supply
Check power supply.
Float switch does not switch
Place float switch in a higher po-
sition.
No flow
Inlet filter clogged
Clean inlet filter with water
stream.
Pressure hose kinked
Adjust hose.
Pump does not switch off
Float switch cannot sink
Place pump properly on the shaft
floor.
Insufficient flow
Inlet filter clogged
Clean inlet filter.
Reduced pumping performance
due to dirty water or water con-
taining abrasive material
Clean pump and replace worn
parts.
The pump switches itself off after
short running period
Thermal switch stops pump due
to waste water.
Pull power plug. Clean pump and
shaft.
Water too hot, thermal switch
stops pump
Ensure that the maximal water
temperature does not exceed
35
℃
.
Technical specifications
Power consumption
(W)
400
Intake voltage
(V)
230
Frequency
(
㎐
)
50
Flow rate
(
ℓ
⁄
h
)
7500
Max. immersion depth
(m)
7
Max. lifting height
(m)
6.5
Max. particle size
(
㎜
)
5
Length of cable
(m)
10