Resistance

 

 

 

The maximum temperature of the pumped liquid should not 35

 

 in continuous oper-

ation.

 

 

Never transfer flammable, gassing, or explosive liquids with this pump.

 

 

Never use the pump for other liquids, especially engine fuels, cleaning agents, and other chem-
ical products!

 

 
 

Electrical connection

 

 

 

The electrical connection is made to a 230

 

V ~ 50

 

Hz protective contact socket. Fuse protection 

at least 10

 

A.

 

 

The indicator lamp inside the switch lights up when the engine is switched on.

 

 

The motor is protected against overloading or blocking by the thermal motor protection built-in. 
In case of overheating, the overheating protection of the motor switches the pump off automat-
ically. After cooling down, the pump automatically switches on again.

 

 
 

Installation

 

 

The pump is installed as follows: either in a fixed position with fixed piping or in a fixed position with 
flexible piping.

 

 
 

 Please note!

 

 

When installing, make sure that the pump does not hang loose on the pressure line or the power 
cable. The submersible motor pump must be hung up on the supplied handle or rest on the floor 
of the shaft.

 

 

To  ensure  that  the  pump  functions  properly,  the  bottom  of  the  shaft  must  always  be  free  of 
sludge or other dirt.

 

 

If the water level is too low, the sludge in the sump can dry up quickly and prevent the pump 
from starting. It is therefore necessary to check the submersible motor pump regularly by per-
forming a start-up test.

 

 

The float switch is set so that it can be put into immediate operation.

 

 

Note: 

The pump shaft should have at least the dimensions of 40×40×50

 

cm so that the float switch can 

move freely.

 

 
 

Mains connection

 

 

This waste water pump is already provided with a safety plug. The pump is intended for connection to a 
safety  socket  with  230

 

V  ~  50

 

Hz.  Make  sure  that  the  socket  is  adequately  fused  (at  least  6

 

A)  and 

functional. Insert the pump plug into the socket, the pump is ready for operation.

 

 
 

Important: 

If the power cord or plug is damaged due to external influences, never repair them yourself! 

The cable must be replaced with a new one, a job that should only be carried out by a qualified electri-
cian.

 

 
 

Functionality

 

 

The pumps are equipped with an open or closed impeller mounted at the end of the drive shaft. They 
are surrounded by a large, circular chamber and a base plate with a mechanical interior. The suction 
opening inside the base plate is in direct contact with the liquid to be pumped. The rotating impeller 
transfers  kinetic  energy  centrifugally  into  the  circular  chamber,  where  part  of  the  kinetic  energy  is 