Working principle
The pumps are equipped with an open or closed rotor mounted to the end of the driving shaft. It is
surrounded by a big circular chamber and a base plate with mechanical inner parts. The suction orifice
of the base plate is in direct contact with the liquid to be pumped. The rotor transfers kinetic energy
(motion energy) with a centrifugal movement to the circular chamber where parts of it are transformed
into pressure energy. The special design of the rotor optimises the hydraulic performance without hin-
dering the pump from transporting muddy liquids with solid matter and short fibres obstruction-free.
Steps of use
1.
Connect the hose to the water pump.
2.
Put the pump into the water.
3.
Connect the pump to the power supply.
4.
Switch on the pump.
Technical specifications
Intake voltage
(V)
230
Intake frequency
(
㎐
)
50
Input current
(A)
2.8
Power consumption
(W)
370
Hose diameter
(
㎜
)
25.4
Connections
(
㎜
)
26.16 (¾″)
Hose diameter
(
㎜
)
25.4
Length of cable
(m)
8
Hose length
(m)
20
Max. immersion depth
(m)
5
Particle size
(
㎜
)
4
Rotation speed
(
r
⁄
min
)
2850
Power
(
㎾
)
0.37 (0,2
hp)
Max. flow rate
(
ℓ
⁄
h
)
1500
Suction up to
(
㎜
)
approx. 70
Lifting height
(m)
8–16
Protection class
IP X8
Material
Aluminium