background image

 

https://www.XPOtool.com 

 

Item 61017

 

Page 3

 

The Tool Experts

 

 

  

 

04 2022

-1

 

 

Introduction

 

 

Thank you for purchasing this quality product.

 To minimise the risk of injury we urge that our clients 

take some basic safety precautions when using this device. Please read the operation instruc-
tions carefully and make sure you have understood its content.

 

Keep these operation instructions safe.

 

 
 

Operating and safety notes

 

 

 

Before commissioning the compressor, it is necessary to read the operating manual thoroughly.

 

 

The compressor should be placed in a dry and aired room. Keep the device away from flamma-
ble objects and chemicals.

 

 

The time of non-use should not exceed two years. If the time of non-use is longer, the compres-
sor should be turned on approximately every 4

 

weeks for approximately 15

 

min.

 

 

Before using the compressor, it is necessary to carry out the required maintenance works and 
check-ups.

 

 

Drops and shocks should be avoided. The compressor needs to stand on a stable and even 
ground. It must not stand sloped during transport or use.

 

 

Make sure that all open connections are closed with protective caps during transport to avoid 
pollutants and water from entering.

 

 

To ensure a good performance, the compressor should stand in an aired, clean, and cool area. 
Dusty or dirty air as well as high temperatures in the surrounding need to be avoided.

 

 

Make sure that the compressor is switched off before connecting it to the electricity. After con-
necting it, it can be switched on. The voltage must not exceed or fall below the nominal voltage 
by more than 10

 

%.

 

 

The air compressor must not get wet. To avoid damages, it must not be placed in a wet area.

 

 

Do not touch any hot components such as cylinder head, exhaust pipe, and check valve to avoid 
burns.

 

 

The electrical cable needs to comply with the power requirement. The cable must not be too 
long, otherwise it affects the starting procedure and the performance of the air compressor.

 

 

Do not store the compressor outside and protect it from direct sun light.

 

 

 Warning:

 Disconnect the power supply and drain the system before attempting to install, transport, 

or service it! Follow all local electrical and safety regulations!

 

 Caution:

 Never use an extension cord with this product. Use an additional air hose instead of an 

extension cord to avoid outages and permanent engine damage. The use of an extension cord will void 
the warranty.

 

 
 

Technical data

 

 

Power

 (W)

 

750

 

Electricity supply

 

230

 

V ~ 50

 

Hz

 

Rated speed

 (

r

min

)

 

1415

 

Flow rate

 (

min

)

 

98

 

Max. working pressure

 (

)

 

8 (115

 

psi)

 

Tank capacity

 (ℓ)

 

24

 

Net weight

 (

)

 

20

 

 
 

 

Содержание 61017

Страница 1: ...instructions and safety information before using for the first time Technical changes reserved Due to further developments illustrations functioning steps and technical data can differ insignificantly Updating the documentation If you have suggestions for improvement or have found any irregularities please contact us ...

Страница 2: ...y avoided If you should find a mistake or wish to make a suggestion for improvement we look forward to hearing from you Send an e mail to service wiltec info or use our contact form https www wiltec de contacts The most recent version of this manual in various languages can be found in our online shop via https www wiltec de docsearch Our postal address is WilTec Wildanger Technik GmbH Königsbende...

Страница 3: ...To ensure a good performance the compressor should stand in an aired clean and cool area Dusty or dirty air as well as high temperatures in the surrounding need to be avoided Make sure that the compressor is switched off before connecting it to the electricity After con necting it it can be switched on The voltage must not exceed or fall below the nominal voltage by more than 10 The air compressor...

Страница 4: ...ressure switch please remove its cover and adjust the turning screw within Turn it clockwise to increase the air pressure and turn it counter clockwise to decrease it Note Always pull the plug to disconnect the compressor from the power supply before any kind of adjustments or repairs maintenance work is carried out Repairs and maintenance Any maintenance work must only be executed after the power...

Страница 5: ...ec tor cuts the power frequently Voltage is too low Check the voltage must not be 10 lower than rated voltage Bad ventilation and high tempera ture Move the compressor to a ventilated area Air pressure is re duced when the ma chine is turned off Air pipe loose or leaking Check and fix it Water drain valve open Tighten the drain valve Check valve leakage Remove and clean it replace when neces sary ...

Страница 6: ...https www XPOtool com Item 61017 Page 6 The Tool Experts 04 2022 1 Exploded view and parts list ...

Страница 7: ... socket head cap screws M5 50 12 41 Observing hole 2 14 Connection pipe 2 42 O ring for observation hole 2 15 Connection pipe sealing circle 2 43 Drainage valve 1 16 Pan head screws with cross recess M4 6 2 44 Air tank 1 17 Limiting stopper 2 45 Washer holding screws 2 18 Air outlet valve clack 2 46 Big foot washer 2 19 Valve plate 2 47 Foot washer holding screw cap 2 20 Air intake valve clack 2 4...

Страница 8: ...separate col lection system for these appliances The logo on the article or on its packaging points out that this article must not be treated as normal house hold waste but must be disposed to a recycling collec tion point for electronic and electrical waste equipment By contributing to the correct disposal of this article you protect the environment and the health of your fellow men Environment a...