background image

Troubleshooting

Spare parts

THE UNIT DOES NOT OPERATE:

•  Is the unit plugged in?

•  Is the house electricity on?

•  Is the room temperature below 5

°

C or above 32

°

C?  If so, then it is out of the working range of the unit.

•  Ensure the ON/OFF switch is turned on.

•  Check the water tank is located properly in the unit and it is not full.

•  Make sure the air inlet and outlet are not obstructed.

THE UNIT SEEMS TO DO NOTHING

:

•  Is the filter dusty, contaminated?

•  Is the air intake or outlet blocked?

•  Is the room humidity already quite low?

THE UNIT SEEMS TO DO LITTLE

:

•  Are too many windows or doors open?

•  Is there something in the room producing lots of humidity?

THE UNIT IS TOO NOISY:

•  Check whether the unit is sitting on a level surface.

THE UNIT IS LEAKING:

•  Make sure the unit is on a level surface and the water tank is fitted correctly

•  Check that the water tank is not damaged.

Selected replacement parts are available from our sister company website: www.dimplex.co.uk

Recycling: For electrical products sold within the European Community.  

At the end of the electrical products useful life it should not be disposed of with 

household waste.  Please recycle where facilities exist. Check with your Local Authority 

or retailer for recycling advice in your country.

13

Содержание XPCDH10

Страница 1: ...uction Manual Models XPCDH10 12 14 These products fully comply with all current European Safety Standard requirements for Dehumidifiers and are fully compliant with the Low Voltage Directive 2014 35 E...

Страница 2: ...lectric heaters stoves or other sources of ignition When defrosting and cleaning the appliance do not use any tools other than those recommended by the manufacturing company The appliance must be plac...

Страница 3: ...Please ask a professional service agent to repair the product Improper repair may cause danger to users Disconnect the appliance from mains power whenever it is not in use before relocating it and bef...

Страница 4: ...appliance is not in use microorganisms can grow in stagnant water the water tank should be emptied and cleaned regularly and properly Empty the tank clean and dry it when not in use and before puttin...

Страница 5: ...or insert any object into any openings Do not use the appliance in locations where paint petrol or other flammable liquids are used or stored Do not use bug sprays or other flammable cleansers vapour...

Страница 6: ...xtension lead may become overload Where there is risk of fire or close to a naked flame Where the power cable may be damaged On a slope or uneven surface Where it may be damaged by chemicals If there...

Страница 7: ...Reciprocating Maximum Suction Pressure MPa 0 85MPa 0 85MPa 0 85MPa Maximum Discharge Pressure MPa 2 2MPa 2 2MPa 2 2MPa Maximum Pressure of Coil MPa 9 6MPa 9 6MPa 9 6MPa Refrigerant R290 GWP 3 Refrige...

Страница 8: ...air then passes through the condenser where it is slightly warmed and re enters the room at a slightly elevated temperature N B As with all compressor type dehumidifiers their effectiveness is reduce...

Страница 9: ...ced on a level surface and that there is a minimum of 50cm 20 of space on either side of the unit to allow for efficient airflow This dehumidifier is fitted with castors for extra mobility if you move...

Страница 10: ...ton to turn on the unit The compressor will start to work in continuous mode 3 To turn off the unit press ON OFF button again 4 When the water tank is full the Full Water indicator will light up Remov...

Страница 11: ...midity levels the water tank will require more frequent emptying In this situation it may be more convenient to set the unit up for continuous drainage this can be done as follows 1 Pull out the water...

Страница 12: ...filter and set aside carefully Use a vacuum cleaner or tap the plastic air filter lightly for easy cleaning If the filter is particularly dirty use warm water with a small amount of medium strength d...

Страница 13: ...HE UNIT SEEMS TO DO LITTLE Are too many windows or doors open Is there something in the room producing lots of humidity THE UNIT IS TOO NOISY Check whether the unit is sitting on a level surface THE U...

Страница 14: ...ges before any chargeable service is carried out What is not covered by a Xpelair Guarantee The Xpelair guarantee does not cover any of the following Any fault or damage to your Xpelair product due to...

Страница 15: ...he property of Xpelair Any repairs performed under the Xpelair guarantee will not extend the guarantee period Any replacement of your Xpelair product by Xpelair during the guarantee period will start...

Страница 16: ...implex Heating and Ventilation Millbrook House Grange Drive Hedge End Southampton SO30 2DF Glen Dimplex All rights reserved Material contained in this publication may not be reproduced in whole or in...

Отзывы: