background image

10

Do’s and Don’ts

Do read the entire instruction leaflet before commencing installation.

• 

Do install the transformer with a double pole isolating switch.

Do make sure that the mains supply is switched off before attempting to make electrical connections or 
carry out any maintenance or cleaning.

Guarantee.

Customers outside UK – see International below.

UK. The Ventilator is guaranteed against defects for 3 years from the date of purchase.

Please keep your purchase receipt.

If you have any problems, contact Xpelair’s Head Office at the address shown below.

Technical advice and service.

Customers outside UK – see International below.

UK: Xpelair have a comprehensive range of services including:

Free technical advice from Engineers on all aspects of ventilation.

Free design service, quotations and site surveys.

Service and maintenance contracts to suit all requirements.

Please ask for details:

• 

By telephone on Techline:
+44(0) 8709 000430

• 

By Fax on Techfax:
+44(0) 8709 000530

• 

At the address below.

Head Office, UK sales office and spares.

GDA Applied Energy Ltd, Morley Way, Peterborough, PE2 9JJ, England

Telephone: 

+44 (0) 1733 456789

Fax: 

+44 (0) 01733 310606

Sales Hotline: 

+44 (0) 8709 000420

http:\\www.xpelair.co.uk

International

Guarantee: Contact your local distributor or Xpelair direct for details.

Technical Advice & Service: Contact your local Xpelair distributor.

Eclipse - Oxplaire  12/4/00  6:52 pm  Page 10

Содержание XHR150PC

Страница 1: ...educe dust mite eliminate mould growth or dampness and condensation and to provide warmed fresh air April 2000 These appliances are intended for connection to fixed wiring Check that the electrical ra...

Страница 2: ...an be adjusted by turning the thumbwheel as shown on page 2 We recommend that it is initially set to number 6 on the scale which is suitable for most locations Turning the thumbwheel clockwise decreas...

Страница 3: ...ric Requirements of all authorities concerned must be observed for exhaust air discharge and intake flow rates a Survey the property carefully and identify the best site for the ventilator Condensatio...

Страница 4: ...masonary does not fall injure people or damage property below e Measure the length of the hole between the outside brick face and inner plaster work Now cut the outer tube accurately to the required l...

Страница 5: ...ive gently against the wall compressing the adhesive Then pull the tube into the room leaving the finisher in place Ensure that the finisher does not fall v Now manipulate the finisher to expand it ou...

Страница 6: ...or in the direction you have determined for the transformer or remote control Fit screw plugs into the screw holes l Fit the wall plate onto the open end of the large tube fitted with the outside cowl...

Страница 7: ...ble isolating switch with a minimum contact gap of 3mm wall or ceiling mounted If metal switch boxes are used earthing regulations must be following Suitably rated 2 core cable 3 mm electricians screw...

Страница 8: ...wn on page 1 being extinguished p After the system has run for some time check the fan unit switches to boost by directing steam from a kettle over the remote control unit q The fan s continuous trick...

Страница 9: ...depending on the location of the remote transformer humidity assembly in the room Fine tuning may be required for precise operation Clockwise allows boost to operate during darkness Anti clockwise pr...

Страница 10: ...and service Customers outside UK see International below UK Xpelair have a comprehensive range of services including Free technical advice from Engineers on all aspects of ventilation Free design ser...

Отзывы: