Technical data:
Technical data
Units
Specification
Voltage / Frequency
V / Hz
~ 220-240V / 50-60 Hz
Max. current consumption
A
0.60
Power consumption - Speeds 1, 2, 3
W
26 / 48 / 80
Air – volume flow rate - Speeds 1, 2, 3
mƒ/h
50 / 100 / 150
Air volume flow rate at 90 Pa Static Pressure
Pa
150m
3
/h
Protection category
IP
20
Max. ambient temperature
„C
50
Dimensions (without ducting) - W x H x D
mm
600 x 595 x 425
Weight of appliance
Kg
17.5
Air connections
mm
125
Condensate pipe connections
mm
20
Filter class
-
G4
Efficiency of heat exchanger
%
Up to 90%
Sound pressure level (measured at a distance of 1m) - Speeds 1, 2, 3
Sound pressure level (measured at a distance of 3m) - Speeds 1, 2, 3
dB (A)
29.5 / 32.0 / 39.0
20.0 / 22.5 / 29.5
6.6
Applied Energy accessories for manual or automatic operation:
Description
Part
Number
Notes
MS2 controller
23513AW
The manual 2-speed switch is suitable for the Xcell 150 QV model
only. This switch can be flush or surface mounted.
QCO
2
controller
96003AA
The CO
2
sensor is suitable for the Xcell 150 QVW model only.
Only 1 off CO
2
sensor can be used per MVHR unit.
Q3SP controller
96005AA
The automatic 3-speed switch is suitable for the Xcell 150 QVW model
only. This switch can be flush or surface mounted.
QHS sensor
96009AA
The Humidistat sensor is suitable for the Xcell 150 QVW model only.
Note:
1.
When using Humidistats in conjunction with the Q3SP 3-speed
switch a maximum of 4 Humidistats can be connected.
2.
When using Humidistats in conjunction with the Q3SP 3-speed
switch and a CO
2
sensor a maximum of 3 Humidistats can be
connected.
Air filter box (without filter)
45014AA
This additional filter box may be fitted to the MVHR system to protect
allergy sufferers against environmental pollution with the use of finer
filters. The filter box is installed immediately after the supply air outlet.
Class F5 or F7 panel filters are available as the filter elements.
Class F5 panel filter for air
filter box
95045AA
F5 filter used in the air filter box only.
Class F7 panel filter for air
filter box
95047AA
F7 filter used in the air filter box only.
Defrost Heater Unit
44001AA
This defrost heater unit may be fitted to the MVHR ducting system to
pre-heat the air intake from atmosphere to prevent the build up of ice
in the heat exchanger when the external air temperatures are below
freezing.
6.7
Applied Energy spares available:
Description
Part Number
Terminal Cover
44301SK
Heat Exchanger
44302SK
Motor (Outgoing Air)
44303SK
Motor (Supply Air)
44304SK
G4 Filters (pack of 2)
44305SK
Control PCB
44306SK
20mm Cable Clamp
44307SK
12mm Cable Clamp
44308SK
Содержание Xcell 150 QV
Страница 8: ...8 5 8 Installation dimensions...
Страница 23: ...23 11 Customer Notes to record details of filter recuperator cleaning etc...
Страница 24: ...24 Customer Notes continued...
Страница 25: ...25 Customer Notes continued...
Страница 26: ...26 Maintenance Log Date Action Signature Stamp...
Страница 27: ...27 This Xpelair MVHR was purchased from Supplier stamp On ________________________ date...