• Not where ambient temperatures

are likely to exceed 50°C.

• If installed in a kitchen fans must

not be mounted immediately
above a cooker hob, or eye
level grill.

• If installing in a room containing a fuel

burning device which has a non-balanced
flue, it is the installer’s responsibility to
ensure that there is enough replacement
air to prevent fumes being drawn down
the flue when the fan is operating up
to maximum extract. Refer to Building
Regulations for specific requirements.

• Exhaust air must not be discharged into

a flue used for exhausting of fumes from
appliances supplied with energy other
than electric. Requirements.

• Not suitable for use in possible chemical

corrosive atmospheres.

Installation

What the installer will need.

• 3mm electrician’s screwdriver

and No.1 or 2 Pozidrive

screwdrivers.

If wall mounting the fan, you will also need:

• A 100mm diameter prepared hole.

• An appropriate external Wall Grille and

Ø100mm wall sleeve duct. Kit Ref 91232AW.

If ceiling mounting the fan, you will also 
need:

• A 100mm diameter prepared hole.

• Appropriate ancillaries for termination. These

items are available from Xpelair:

1. 3m flexible ducting Ref: 89663AA. If the

duct passes through a cold space use

insulated duct ref: 89847AA.

2. Soffit Grille Ref: 89742AW.

3. XCT100 – Condensation Trap. Ref:

89749AA. Fitted immediately above the

fan, this prevents water ingress due to

condensation forming in the duct above

the fan and running down.

If surface mount wiring the fan, you will 
also need:

• Miniature PVC trunking 16mm wide x 8mm

deep to house the cable to the fan.

Installing the isolating switch 
and cables.

A means for disconnection in all 

poles must be incorporated in 

the fixed wiring in accordance with wiring 

regulations

• If metal switch boxes are used, earthing

regulations must be followed.

• The cross-sectional area of the supply cord

used should be ranged from 1-1.5mm².

• C4S / C44R / C4PS / C4PR – 2 core, C4TS /

C4TR / C4HTS / C4HTR – 3 core.

• C4TS / C4TR / C4HTS / C4HTR. A wall or

ceiling On/Off switch (with indicator light) is

recommended

1. Check that the electrical rating shown

inside the back-plate matches your mains
supply.

2. Check there are no buried pipes or cables

e.g. electricity, gas, water behind the
switch location (in the wall or above the
ceiling). If in doubt, seek professional
advice.

3. Isolate the mains supply.

4. Lay in the cable from the isolating switch

to the fan location via the on/off switch (if

required). This must be housed in miniature

PVC trunking.

5. Lay in the cable from the isolating switch to

the point of connection to the mains supply.

Warning: Do not make any 
connections to the electrical 
supply at this stage.

6. Install the isolating switch and on/off switch

(if required).

7. Make all connections within the isolating

switch and the on/off switch (if required).

Wet Rooms: On/Off switch must 
be situated so that it cannot be 
touched by persons making use of 
the bath or shower.

For Australia Only – C4S /C4R / C4PS / 
C4PR

Connection to the supply can be made by a 

flexible 2-core cable complete with 3 pin plug 

for insertion into an approved 10A GPO or 

directly wired through an approved 10A wall 

mounted surface switch with at least 3mm 

clearance between contacts.
For Australia Only – C4TS / C4TR / C4HTS / 
C4HTR

These models are permanently connected to 

the supply and operation is controlled by a 

remote switch. They should be directly wired 

to the supply through an approved 10A wall 

mounted surface switch with at least 3mm 

clearance between contacts.

EnglishEnglish

Содержание Simply Silent C4S

Страница 1: ...C4S 92960AW C4R 92961AW C4TS 92962AW C4TR 92963AW C4PS 92964AW C4PR 92965AW C4HTS 92966AW C4HTR 92967AW Xpelair Simply Silent Contour English Installation and Maintenance Instructions...

Страница 2: ...supply is switched off before attempting to make electrical connections or carry out any maintenance or cleaning Please leave this leaflet with the fan for the benefit of the user Standard C4S 92960A...

Страница 3: ...at installation Built in back draught shutter C4S C4R Operate the fan using an on off switch not supplied C4PS C4PR Operate the fan using an integral pull cord C4TS C4TR Built in timer operates fan f...

Страница 4: ...TE Fan switches on at lower level of condensation anti clockwise MORE SENTITIVE RH 50 Fan runs on for a shorter time when the external switch is turned off Fan does not switch on until higher level of...

Страница 5: ...CUSTOMER CONNECTION TERMINAL SET JUMPER TO REQUIRED POSITION FOR SPEED SETTING SET JUMPER TO REQUIRED POSITION FOR SPEED SETTING CUSTOMER CONNECTION TERMINAL CUSTOMER CONNECTION TERMINAL LOW SPEED HI...

Страница 6: ...poles must be incorporated in the fixed wiring in accordance with wiring regulations If metal switch boxes are used earthing regulations must be followed The cross sectional area of the supply cord u...

Страница 7: ...to the wall duct ceiling as before 9 Fasten the back plate to the wall ceiling using appropriate fasteners See figure A 10 If using screws do not over tighten The fan may also be fixed to a wall tube...

Страница 8: ...sembly by hooking in the top first and then swing the cover down to clip into place If surface mount wiring break out the thin wall section in the front cover prior to re fitting see figure E The mini...

Страница 9: ...By telephone on Techline 44 0 844 372 7766 By fax on Techfax 44 0 844 372 7767 At the address below Head Office UK Sales Office and Spares Redring Xpelair Group Ltd Newcombe House Newcombe Way Orton S...

Страница 10: ...Office UK Sales Office and Spares Redring Xpelair Group Ltd Newcombe House Newcombe Way Orton Southgate Peterborough PE2 6SE England Telephone 44 0 844 372 7761 www xpelair co uk www xpelair co uk int...

Отзывы: