Wire the electrical connections
•
Make sure the mains supply is isolated,
1. Wire the fan as shown in
figure D
check the fan model to diagram, feeding the
cable between the two raised pegs, if wiring from above, and through labyrinth to
terminal block.
2. Switch off the mains electrical supply and remove fuses
3. Connect the cable from the isolating switch to the electrical supply wiring.
• For fixed wiring circuits the protective fuse for the appliance must not exceed
5A.
DX100BT only – (fig. E)
• To adjust the over-run period turn the control (T) clockwise to increase and anti-
clockwise to decrease.
DX100BHT & DX100BHPT only – (fig. F)
The pre-set humidity operation is factory set at approximately 75% Relative Humidity
(RH), but can be adjusted between 65% and 85% RH by control H.
The over –run timer is factory set to approximately 20 mins, but can be adjusted
between 2 mins and 30 mins by control T.
Both controls are adjustable. Turn the controls clockwise to increase RH or time,
and anti-clockwise to decrease
.
Using the fan
DX100B
';%%3
only
• Operate the fan using the on/off switch. Repeat to switch off.
DX100BP only
• Operate the fan by pulling and releasing the cord. Repeat to switch off.
DX100BT only (fig. E)
• Operate the fan using an on/off switch. When the switch is turned off, the fan
continues to operate for the set time delay. To adjust the over-run period, turn the
control “T” clockwise to increase and anti-clockwise to decrease.
DX100BHT only
• The fan automatically adjusts to slow changes in natural humidity levels without
operating the fan. If the humidity levels increase at a rate slower than 5% RH in 5
minutes, up to the pre-set humidity level, the fan will not be triggered by humidity. This
is to prevent nuisance triggering of the fan. If humidity levels increase quicker than 5%
RH in 5 minutes the fan will operate. When relative humidity drops the fan continues to
operate for the adjustable time delay.
DX100BHPT only
• Automatic mode - The fan automatically adjusts to slow changes in natural humidity
levels without operating the fan. If the humidity levels increase at a rate slower than
5% RH in 5 minutes, up to the pre-set humidity level, the fan will not be triggered by
humidity. This is to prevent nuisance triggering of the fan. If humidity levels increase
quicker than 5% RH in 5 minutes the fan will operate. When relative humidity drops the
fan continues to operate for the adjustable time delay.
Manual mode – Use the integral pull cord switch. When the fan is switched off, it goes
into automatic mode after the time delay. Light indicates when the fan is operating in
manual mode.
Cleaning (This should be done by a qualified electrician)
1. Before cleaning, isolate the fan completely from the mains supply
2. Remove the front cover by pressing the release catches located on the sides of the
unit with a 3mm screwdriver, whilst pulling the front cover forward (fig. G).
3. To clean the front cover, either wipe it with a damp, lint free cloth or wash it with
warm soapy water. Thoroughly dry the front cover and refit.
4. Do not immerse the fan in water or other liquids to clean any other parts of the fan.
5. Do not use strong detergents, solvents or chemical cleaners
6. Allow fan to dry thoroughly before use.
7. Apart from cleaning, no other maintenance is required
Do’s and Don’ts
• Do read the entire instruction leaflet before commencing installation.
• Do install each fan with a means for disconnection in all poles in the fixed wiring.
• Do make sure the mains supply is switched off before attempting to make electrical
connections or carry out any maintenance or cleaning.
• Don’t install this fan in any window/panel, which is less than 3mm thick.
Guarantee
UK only:
We, Applied Energy Products Ltd., provide a guarantee against faulty parts and
manufacture for a period of 3 years from the date of purchase. In the unlikely
event of a product breakdown during the guarantee period the product should
be returned to the place of purchase or to Applied Energy Products Ltd.
Exclusions: This guarantee does not cover;
• Compensation for the loss of the product or consequential loss of any kind.
• Damage or defects to the product arising from incorrect installation.
• Transportation costs.
This guarantee does not affect your statutory rights
echnical advice
and service
Customers outside UK - see international below.
UK: Xpelair have a comprehensive range of services including:
•
Free technical advice help-desk from Engineers on all aspects of ventilation.
•
Free design service, quotations and site surveys.
•
Service and maintenance contracts to suit all requirements.
Please ask for details:
•
By telephone on Techline: +44 (0) 844 372 7766
•
By fax on Techfax: +44 (0) 844 372 7767
•
At the address below
Head Office, UK Sales Office and Spares
Applied Energy Products Ltd, Morley Way, Peterborough, PE2 9JJ England
Telephone: +44 (0) 844 372 7761
Fax: +44 (0) 844 372 7762
Sales/Spares Hotline: +44 (0) 844 372 7750
Sales/Spares Faxline: +44 (0) 844 372 7760
www.xpelair.co.uk
International
•
Guarantee: Contact your local distributor or Xpelair direct for details.
•
Technical Advice and Service: Contact your local Xpelair distributor.
A4 Leaflet : Part No.
24
216
AA
(Revision
A
)
A
B
C
D
E
F
G