For Australia Only – LV100R / LV100S / LV100PR / LV100PS / LV100PIRR / LV100PIRS 

Connection to the supply can be made by a flexible 2-core cable complete with 3 pin plug for insertion into an approved 10A 

GPO or directly wired through an approved 10A wall mounted surface switch with at least 3mm clearance between contacts. 

For Australia Only –LV100TR / LV100TS / LV100HTR / LV100HTS / LV100HPTR / LV100HPTS 

These models are permanently connected to the supply and operation is controlled by a remote switch. They should be directly 
wired to the supply through an approved 10A wall mounted surface switch with at least 3mm clearance between contacts. 

 

 

Preparing the Fan for installation. 

1.

 

Remove the front cover by depressing the latch on the underside of the cover and pulling off the front cover from the 

bottom (See Figure C). 

 

 

 

 

 

 

Mark the position of the back-plate 

2.

 

Hold the back-plate so that the level line marked on it is orientated horizontally. 

3.

 

Carefully insert the fan tube into the wall duct. 

4.

 

Mark on the wall the positions of the fixing holes in the back-plate. 

5.

 

Remove the back plate from the ducting. 

6.

 

Drill screw holes in these positions if necessary, and fit wall plugs and screws as required.  

 

 

 

 

 

 

Mount the back-plate. 

7.

 

Push the ribbed gasket onto the duct section of the back plate (see Figure D). 

8.

 

Push the larger diameter piece of the telescopic wall tube onto the ribbed gasket. Cut the tube to the required size 

first if necessary. 

9.

 

Feed the mains cable through the cable entry hole in the back plate to the terminals. 

10.

 

Insert the fan tube into the wall duct/ceiling as before. 

11.

 

Fasten the back-plate to the wall/ceiling using appropriate fasteners supplied. See figure A. 

12.

 

If using screws, do not over tighten.  

 

Mount the back draft shutter

 

13.

 

Peel the backing from the foam strip supplied and attach it around the outside lip on the backdraft shutter. 

14.

 

Go outside. Holding open the top and bottom vanes insert the lip into the wall duct. 

15.

 

Making sure that the back draft shutter is level, mark the positions of the two fixing holes in the top right hand and 

bottom left hand corners. 

16.

 

Remove the back draft shutters from the wall duct. 

17.

 

Drill screw holes in marked positions and fit the remaining wall plugs. 

18.

 

Holding open the top and bottom vanes, refit the back draft shutter and fasten it to the wall using the screws. Do not 

overtighten screws. 

19.

 

Make sure that the vanes open and shut fully. 

 

Mounting the transformer (Figure F) 

The transformer can be fixed directly to the wall. 

When wall mounting, the transformer must be orientated as shown in Figure G to fulfil ingress protection requirements. 

20.

 

Remove the screws securing the cover, remove the cover. 

21.

 

Position the transformer on the wall and mark the two fixing holes ‘A’ and ‘B’. 

22.

 

Drill and plug the two holes and fix the transformer to the wall. 

THE TRANSFORMER MUST NOT BE COVERED BY LOFT INSULATION 

 

Wire the electrical connections. 

23.

 

Make sure the mains supply is isolated. Switch off the mains electrical supply and remove fuses. 

24.

 

Feed the cable to the terminal block. Wire the fan as shown in Figure J using the diagram appropriate to the fan model. 

25.

 

Connect the cable from the isolating switch to the electrical supply wiring. 

 

 

If working above ground floor level, safety precautions must be observed. 

 

 

If installing in a ceiling, appropriate termination ancillaries are required. Follow 

instructions provided. 

 

Содержание 93011AW

Страница 1: ...et before commencing installation Do install each fan with a means for disconnection in all poles in the fixed wiring Do make sure the mains supply is switched off before attempting to make electrical...

Страница 2: ...gral pull cord switch In automatic mode the built in timer automatically operates the fan for a pre set delay time from 30 seconds to 30 minutes once humidity drops below the pre set Relative Humidity...

Страница 3: ...Back plate fixing positions Front Cover Removal Depress Cover Latch with tool remove Cover A C B...

Страница 4: ...Minimum 30 seconds Maximum 30 minutes Factory settings Timer 15 minutes RH 75 D E H F G...

Страница 5: ...Wiring and setting up I1...

Страница 6: ...ract Refer to Building Regulations for specific requirements Exhaust air must not be discharged into a flue used for exhausting of fumes from appliances supplied with energy other than electric Requir...

Страница 7: ...ated 2 core cable supply to transformer LV100R LV100S LV100PR LV100PS LV100HTR LV100HTS LV100HPTR LV100HPTS LV100PIRR LV100PIRS Suitably rated 3 core cable supply to transformer LV100TR LV100TS 1 Chec...

Страница 8: ...e back plate to the wall ceiling using appropriate fasteners supplied See figure A 12 If using screws do not over tighten Mount the back draft shutter 13 Peel the backing from the foam strip supplied...

Страница 9: ...ion LV100TR LV100TS LV100PIRR LV100PIRS only To adjust the over run period turn the control T clockwise to increase and anti clockwise to decrease see Figure H LV100HTR LV100HTS LV100HPTR LV100HPTS on...

Страница 10: ...Automatic mode The fan automatically adjusts to slow changes in natural humidity levels without operating the fan If the humidity levels increase at a rate slower than 5 RH in 5 minutes up to the pre...

Страница 11: ...This page has been left blank for the addition of any notes you may wish to make...

Страница 12: ...or Glen Dimplex UK Ltd Glen Dimplex Europe Limited Millbrook House Grange Drive Hedge End Southampton SO30 2DF Airport Road Cloghran Co Dublin K67 VE08 Telephone 44 0 344 879 3588 Telephone 353 0 1 85...

Отзывы: