12 

December 2020 

 08/100245/0           

 

 

Additional Information 

Technical Data 

Speed 

Air flow rate (l/s) 

Power (W) 

Trickle 

30 

5.5 

Sp.1 

45 

Sp.2 

60 

14 

Switches and Controller Options 

 

Manual Override Switch MOS (Supplied) 

Ref. 90199AW 

 

Change Over Switch COS 

Ref. 90108AW

 

 

Passive Infrared Sensor XPIRA 

Ref. 21871AA

 

 

Remote Humidistat XRH 

Ref. 21856AW 

 

Time Delay Unit DT20B 

Ref. 21850AW

 

 

Air Quality Sensor AQS 

Ref. 92097AW

 

 

Three Speed Selector Switch 

Ref. 91266AW 

 

Three Speed Controller 

Ref. 91457AA

 

Ancillaries

 

Duct Heater 

 Ref. 300001022 

 

Raises the temperature of incoming air above 10

°

C during sub-

zero conditions. Supplied as standard with the XELH version of 

this ventilation unit. 

 
 

Three-Storey Kit (XEL3SK) 

Ref. 111067 

 

Includes a 200mm diffuser with an intumescent element which 

expands in the event of a fire to restrict air flow and delay the 

spread of the fire. 

 

Содержание 110015

Страница 1: ...ts reserved Material contained in this publication may not be reproduced in whole or in part without prior permission in writing of Glen Dimplex Glen Dimplex UK LTD trading as Glen Dimplex Heating Ven...

Страница 2: ...nit via the G4 filter on the cover The casing incorporates a 125mm spigot for easy connection to the supplied ducting Safety Instructions This ventilation unit is intended exclusively for the ventilat...

Страница 3: ...fuser Mounting Ring 8 200mm Supply Air Diffuser 9 Duct Heater Everdri XELH Version Only Position of air supply diffuser It is recommended that the supply air diffuser is installed in a central locatio...

Страница 4: ...Care should be taken to ensure ducting is as straight and uncompressed as possible with minimal bends This will reduce resistance in the air flow path allowing greater performance at lower speed setti...

Страница 5: ...erature probe from the heater as shown on the right 9 Push the adapter onto the installed diffuser mounting ring NOTE When testing the ventilation unit check the ducting for any air leaks and seal wit...

Страница 6: ...Firmly connect the two sides of the plug Fix the cables by either Routing the cable in the labyrinth Fixing with the cable clamp NOTE If using the labyrinth ensure the cable is securely fitted inside...

Страница 7: ...Speed 2 Control L Trickle Speed Using a small long handle screw driver adjust the potentiometer as required by turning the knob using the central slot Turn clockwise to increase speed Turn anti clockw...

Страница 8: ...8 December 2020 08 100245 0 Alternative Switch Option Connection with a three speed selector switch Connection with sensors or several change over switches...

Страница 9: ...oke or CO detector must be normally closed NC and will go open circuit OC in the event of a fire When the ventilation unit detects an open circuit the fan will stop to prevent feeding fresh air to a f...

Страница 10: ...the extract of cooking smells or moisture laden air When in use it is advisable to open window vents or a window to allow the moisture laden air to escape The middle position would be the normal runni...

Страница 11: ...ours LED on for 2 short flashes 3000 to 4000 hours LED on for 3 short flashes 4000 to 5000 hours LED on for 4 short flashes 5000 to 6000 hours LED on for 5 short flashes 6000 to 7000 hours LED on for...

Страница 12: ...f 21856AW Time Delay Unit DT20B Ref 21850AW Air Quality Sensor AQS Ref 92097AW Three Speed Selector Switch Ref 91266AW Three Speed Controller Ref 91457AA Ancillaries Duct Heater Ref 300001022 Raises t...

Страница 13: ...for 5 years from date of purchase Xpelair reserve the right to repair or replace the unit Keep your purchase receipt Any problems contact the address below Outside the UK See International section In...

Страница 14: ...The ventilation unit has been packaged carefully to protect it from damage during transport The transport packaging consists of recyclable raw materials Please ensure to dispose of it in an environmen...

Отзывы: