16
DISCRIMINATION > EXPERT
Notch
B.CAPS
NOTCH 1
0
37-37
B.Caps rejects the
rusty
beer and fizzy drink bottle caps effectively. Make sure you acti-
vate it on the beach, in parks and polluted zones. B.Cap reject also assists with rejecting
some types of iron which is usually difficult to discriminate, such as ferrous cartridges,
ferrous rings and some larger mis-shaped ferrous.
Adjust the rejection from 0 to 5 with
and
.
Targets processed by the B.Caps parameter are reported as ferrous targets so it is possi-
ble to adjust the iron volume to make them quiet.
B.Caps
(except Prg. 7/8/9)
The Notch complements the discrimination: it enables a "target window" to be rejected
whereas discrimination rejects all targets below a selected threshold. For example, if you
detect an undesirable target in the ground, you can decide simply to reject the corre-
sponding conductivity group and continue to detect targets with a conductivity higher or
lower than those in the rejected group.
If the reference target has a conductivity of 37, adjust with + and - the Notch at 37-37. All
targets with this conductivity will then be silenced.
From Full Tones, press
(3sec).
Customize the sound partitioning of the discrimination range for Full Tones and Adjust
volume levels of each tone independently.
Press
to choose the TONE BREAK (T. BREAK) or the VOLUME (VOL) and set them
using + and - .
Full tones - Threshold and volume settings
T.BREAK
VOL
35
If you set the Notch to 00-00, all the ground (-6.4 to 0) will be silenced.
NOTCH 2
28-46
Select
NOTCH 1
inside
MENU
>
DISCRI
and press
(3 sec).
This advanced notch function enables you to widen the rejection window in the event
that the undesirable target(s) have a fluctuate conductivity. For example, if the undesira-
ble target is generating an ID ranging from 28 to 46, you can use this option to lower the
value of Threshold 1 to 28 and increase Threshold 2 to 46.
Select Tone break 1 or 2 with
(3 sec) .
Adjust the values
and
.
If several targets with different conductivity levels are a problem, you can activate two
other notches: N2 and N3. Use
to select N2 or N3 and adjust as for N1.
Multi-Notch
the OFFSET FT feature allows the user to shift the “Full Tone” audio frequencies of
targets with a signature just above the Discrimination threshold, in order to better
differentiate them audibly from iron.
0 = no offset
5 = (default value) creates a little offset
40 = all targets above discrimination will sound with the same high tone.
Offset Full tones
(Only with Full Tones mode ON)
OFFSET FT
5