IV. Solenoid Valve Installation
CutthetubingbetweenthecarbonblockfilterandtheROmembrane.Install
thesolenoidvalve.
*Arrowonsolenoidvalveindicateswaterflowdirection.
a. RO/DI System without Auto Shut Off (Installation Option 1)
¼”pipefrom
pre-filtration
system
Solenoid
Valve
Note:Filteredwaterisrequiredtopreventsediments
fromcloggingthesolenoidvalve.Donotinstallthe
solenoidvalvebeforeyourfiltrationsystem
RO
Membrane
¼”pipeto
ROinlet
Feedwater
input
SedimentCarbon
Tank/Sump/Reservoir
DIFilter
ROWaste
ConnectthesolenoidvalveattheRO/DIoutput.
ThisoptioncanbeveryhelpfulwhentheRO/DIsystemisremotelylocated.
*Arrowonsolenoidvalveindicateswaterflowdirection.
b. RO/DI System with Auto Shut Off (Installation Option 2)
Tank/Sump/Reservoir
1/4”pipefrom
RO/DIoutlet
SolenoidValve