background image

Installation instructions 

GW0002 works in two network modes: route mode and bridge mode. When it is under the route mode, the IP 
address of WAN port must be at different network segment from that of the LAN port. But when it is under the 
bridge mode, the IP address of WAN port is the same with that of LAN port. 

Network Connection Diagram under Route Mode 

Under the route mode, the default IP address of WAN port is a DHCP IP address, while the default IP address of the 
LAN port is a static IP address, namely 192.168.11.1. 

Note: The IP address of 
LAN port of the GW0002 
device and the IP address 
of PC must be at the 
same network segment, 
while that of WAN port is 
at a different network 
segment. 

 

 

 

 

Network Connection Diagram under Bridge Mode 

Under the Bridge mode, the IP address of WAN 
port is the same with that of LAN port. Generally, 
when the device works under the bridge mode, 
the IP address of the device has been modified. In 
the following diagram, it is assumed that the IP 
address has been modified into 172.16.80.1. 

Note: The IP address of PC and that of WAN port 
of the GW0002 device are at the same network 
segment. 

 

 

 

Log in Web Management System: 

Open a web browser and enter the gateway’s IP address (default IP 

is 192.168.11.1). Then input username and password in the displayed login GUI. Both the default username and 
password are 

admin

 

 

Modify Gatew

ay’s IP Address: 

If you want to modify the IP address of IAD-4S/8S,  

please click ‘Network → Local Network’ in the navigation tree on the left of the Web Management System, and 

then input new IP address and DNS server address on the displayed interface.

 

 

Configure SIP Server:

 Log in the Web Management System of the gateway, and then click SIP Server in the 

navigation tree and then enter the address of the SIP server which is to be registered. Click Save in the last.

 

 

GW0002 
 

GW0002 

Отзывы: