Xorcom CXR2000 Скачать руководство пользователя страница 3

Misgav Industrial Park, POB 60, D.N. Misgav 20174,  Israel

Tel: +972-4-9951999; Fax: +972-4-9990287

 

 

PM0616.05 - CXR2000/CXR3000 CompletePBX Getting Started Guide (electronic version) 

Page 

3

 of 

5

 

nameserver 5.6.7.8

 

4.

 

Run 

systemctl restart network

 in order to apply the changes 

Note

: Correct network parameters settings are extremely important for normal CompletePBX 

functionality.  

Always make sure that the 'localhost' is defined in the /etc/hosts file: 

127.0.0.1   

localhost.localdomain localhost 

Step 4: Configure the CXR2000/CXR3000 

If the unit is equipped with FXS ports they are configured as CompletePBX extensions starting 
from number 3001. 

In order to configure the device follow these steps: 

a)

 

From a computer’s Internet browser enter the CXR2000/CXR3000 IP address (for example 
http://192.168.0.64 ) 

b)

 

You will be prompted to define a password for “administrator”. Once you define a password 
you will be able to connect to the web interface as user 

admin

 with password that you defined.

 

Now you can modify your CXR2000/CXR3000 CompletePBX configuration. See the 

CompletePBX Reference Guide

Step 5: Protect CompletePBX Against Unauthorized Access 

Once you have 

fully

 

configured

 CompletePBX we highly recommend that you use the following 

procedures and applications supported in CompletePBX to protect it against unauthorized access: 

Change the Linux Password  

The password for the Linux root user can be changed by using the Linux 

passwd

 command. 

IP Protection 

CompletePBX must be installed on a protected LAN and must not be directly connected to the 
public Internet.  The LAN must be protected by a Firewall/NAT router. 

Intrusion Detection (fail2ban) and Firewall 

In order to maximize protection from external threats, the 

fail2ban

 process is activated, in addition 

to the internal firewall.  Use the Admin|Security|Firewall and Admin|Security|Intrusion Detection 
dialogs to modify the internal firewall and intrusion detection settings. 

Unit Status LED (Light Emitting Diode) indicators 

The CXR2000/CXR3000 is equipped with varying LED indicators on the front panel, depending on 
the model.  

Digital CXR2000/CXR3000 Models  

These are models that have at least one digital PSTN port – ISDN BRI or PRI. They have a vertical 
array of four status indicators on the left side of the front panel (

Fig 3

).  