Refer any service operation not described in this manual to a qualified technician.

l

Socket outlets used to supply the fixture with power or external power switches must be located near the fixtures and 

easily accessible so that the fixtures can easily be disconnected from power.

PROTECTION FROM  BURNS AND FIRE

l

The  exterior  of  the  fixture  becomes  hot  during  use. Avoid  contact  by  persons  and  materials.                            

Allow  the  fixture  to  cool  for  at  least  10  minutes  before  handling.

l

Keep  all  combustible  materials  (e.g.  fabric,  wood,  paper)  at  least  100  mm   away  from  the  fixture.

l

Keep flammable materials well away from the fixture.

l

Ensure that there is free and unobstructed airflow around the fixture.

l

Do not illuminate surfaces within 200 mm  of the fixture. 

l

Do not attempt to bypass thermostatic switches or fuses.

l

If you relay power from one fixture to another using power throughput sockets, do not connect more than ten the 

fixture in total to each other in an interconnected chain.

l

Connect only other the fixture to fixture power throughput sockets. Do not connect any other type of device to these 

sockets.

l

Do not connect any other type of device to these sockets.

l

Do not stick filters, masks or other materials onto any optical component, besides the optional CLF Yara filters.

l

Do not modify the fixture in any way not described in this manual.

l

Do not use fixture on a dimmer.

PROTECTION FROM INJURY

l

 

Do not look continuously at LEDs from a distance of less than 3 meters from the front surface of the fixture without 
protective eyewear such as shade 4-5 welding goggles. At less than this distance, the LED emission can cause eye 
injury or irritation. At distances of 3 meters and above, light output is harmless to the naked eye provided that the 
eye’s natural aversion response is not overcome.

l

 Do not look at LEDs with magnifiers, telescopes, binoculars or similar optical instruments that may concentrate the 

light output.

l

 Ensure that persons are not looking at the LEDs from within 3 meters when the product lights up suddenly. This can 

happen when power is applied, when the product receives a DMX signal, or when SERVICE menu items are 
selected.

l

 Fasten the fixture securely to a fixed surface or structure when in use. 

l

 Ensure that any supporting structure and/or hardware used can hold at least 10 times the weight of all the devices 

they support.

l

 Allow enough clearance around the fixture to ensure that it cannot collide with an object or another fixture when it 

moves.

l

 Check that all external covers and rigging hardware are fastened securely.

l

 Block access below the work area and work from a stable platform whenever installing, servicing or moving the 

fixture.

l

Do not operate the fixture with missing or damaged covers, shields or any optical component.

Содержание P180

Страница 1: ...LIGHT 4 in 1 LED WASH USER MANUAL...

Страница 2: ...r cables 6 Relaying power to other devices 6 Data link 6 Tips for reliable data transmission 6 Physical installation 7 Fastening the fixture to a flat surface 7 Setup 8 Control panel and menu navigati...

Страница 3: ...Dimensions All dimensions are in millimeters 1 0...

Страница 4: ...l warnings in this manual and printed on the fixture If you have questions about how to operate the fixture safely please contact your supplier PROTECTION FROM ELECTRIC SHOCK l Disconnect the fixture...

Страница 5: ...not modify the fixture in any way not described in this manual l Do not use fixture on a dimmer PROTECTION FROM INJURY l Do not look continuously at LEDs from a distance of less than 3 meters from th...

Страница 6: ...iew Control buttons Safety cable attachment point LCD Display 5P DMX input AC mains power throughput AC mains power input 3P DMX input optional 5P DMX output 3P DMX output optional Antenna wireless so...

Страница 7: ...cuit must be equipped with a fuse or circuit breaker and ground fault earth fault protection Warning Socket outlets or external power switches used to supply the fixture with power must be located nea...

Страница 8: ...to connect the first fixture to AC mains power connectors must be used to draw AC mains power from the fixtures power throughput PowerCON TRUE 1 sockets and yellow connectors must be used to supply po...

Страница 9: ...port at least 10 times the weight of all fixtures and equipment to be installed on it Warning The supporting surface must be hard and flat or air vents in the base may be blocked which will cause over...

Страница 10: ...onfigured by using the DMX ADDRESS menu in the control panel For setting the DMX address press ENTER before you can change the address The main screen will show a dot and the backlight will be switche...

Страница 11: ...9 Macro color 10 AUTO 11 Speed 12 ID 3 COLOR Dimmer 0 255 Default 255 Red 0 255 Default 255 Green 0 255 Default 255 Blue 0 255 Default 255 White 0 255 Default 255 Strobe 0 20 Default 00 4 AUTO AT 1 1...

Страница 12: ...EDIT Programe 01 09 Scene 01 30 Red 0 255 Programe 10 has 90 Scenes Green 0 255 Blue 0 255 White 0 255 Programe 10 Scene 01 90 Strobe 0 20 Time 0 255 Fade 0 255 7 INFO VERSION VX XX USAGE T Xxxx H RE...

Страница 13: ...pecial the light intensity was linear increase with DMX value and light intensity control is finer at low level with DMX values decrease the dimmer speed will also has effect on it Whichever DIMMER CU...

Страница 14: ...Value 000 255 0 100 3 CH Function Value Setting Remark 1 Red 000 255 0 100 2 Green 000 255 0 100 3 Blue 000 255 0 100 4 CH Function Value Setting Remark 1 Dimming 000 255 0 100 2 Red 000 255 0 100 3...

Страница 15: ...robe 3 closing pulse fast slow Shutter open Strobe 4 random strobe fast slow Shutter open Strobe 5 random opening pulse fast slow Shutter open Strobe 6 random closing pulse fast slow Shutter open Stro...

Страница 16: ...0 burst fast slow Shutter open 2 Dimming 000 255 0 100 3 Fixture control settings 000 044 045 049 050 054 055 059 060 064 065 069 070 074 075 089 090 094 095 099 100 104 105 129 130 134 135 139 140 14...

Страница 17: ...0 069 070 079 080 089 090 099 100 109 110 119 120 129 130 139 140 149 150 159 160 169 170 179 180 189 190 199 200 255 No Function Out1 AUTO1 Out2 AUTO2 Out3 AUTO3 Out4 AUTO4 Out5 AUTO5 Out6 AUTO6 Out7...

Страница 18: ...ess control panel function by pressing MODE until ID is displayed 2 Press ENTER increase or reduce ID values by pressing UP DOWN between 01 and 66 3 Press MODE to exit 2 Enable or disable ID SET IDSW...

Страница 19: ...lation Orientation Any Minimum distance to combustible materials 100 mm from fixture Minimum distance to illuminated surfaces 200 mm from fixture Connections AC power input PowerCON TRUE 1 input socke...

Страница 20: ......

Отзывы: