background image

7

Connection of DMX Signal Wire

1

Please use the fixture controller wire specially when use the DMX512 

Controller. Connect the (male) 3 pin connector side of the DMX cable to 
the output (female) 3 pin connector of the first fixture.

2

Connect the end of the cable coming from the first fixture which will have 

a (male) 3 pin connector to the input connector of the next fixture 
consisting of a (female) 3 pin connector. Then, proceed to connect from 
the output as stated above to the input of the following fixture and so on.

3

This product can be connected numerous lamps in series without the 

need for the signal amplifier; the signal will not be weakened.

DMX IN

DMXOU

DMX IN

DMXOU

DMX IN

DMXOU

3-PIN TO 5-PIN CONVERSION CHART

Note!  If  you  use  a  controller  with  a  5  pin  DMX  output  connector,  you  will 

need to use a 5 pin to 3 pin adapter.

Conductor

Ground/Shield

Data ( - ) signal

Data ( + ) signal

Do not use

Do not use

3 Pin Female

(output)

Pin 1

Pin2

Pin 3

5 Pin Male (Input)

Pin 1

Pin2

Pin 3

Do not use

Do not use

 3 PIN TO 5 PIN CONVERSION CHART

Содержание B150

Страница 1: ...1 4 in 1 USER MANUAL LED BAR...

Страница 2: ...ginal factory box and packing AC POWER This fixture has an auto switching switch mode power supply that can accommodate a wide range of input voltages The only thing necessary to do before powering on...

Страница 3: ...ed value Make sure that the cable didn t be damage or lacerated by sharp The light must be power off when it s standing idle or before clearing The cable must with plug and you must pull out the cable...

Страница 4: ...ss Protection IP65 indoor option l Product Size 990X120X145mm l Package Size 1070X160X170 mm l N W 5 7Kg Features l RGBW color mixing with or without DMX controller l special effect minimum 16psc one...

Страница 5: ...5 Product Overview MAINS IN MAINS IN DMX OUT MAINS OUT LED SIGNAL LED SIGNAL MAINS OUT DMX IN DMX IN DMX OUT Dimensions INDOOR OUTDOOR 990 145 100 120...

Страница 6: ...hanging it and make sure the weight of the light is within limits of the hanger l Please make sure without any flammable objects within 0 5m when installing the light l The installation should be oper...

Страница 7: ...Then proceed to connect from the output as stated above to the input of the following fixture and so on 3 This product can be connected numerous lamps in series without the need for the signal amplifi...

Страница 8: ...function Navigates downwards through the menu list and decreases the numeric value when in a function 4 OPERATING INSTRUCTIONS Control Panel Functions MAIN FUNCTION SUB FUNCTION SELECTION 001 512 000...

Страница 9: ...of the fastest dimming curves 4 for the most slowly dimming curve Version number Enables or Disables password lockout amount set of combined lights number set of combined lights Operating instruction...

Страница 10: ...isplayed Press ENTER button select DMX channel by pressing UP DOWN Press MODE to exit DMX512 Channel Values 4 channels Channel 1 2 3 4 Channel 1 2 3 4 5 6 Value 000 255 000 255 000 255 000 255 Value 0...

Страница 11: ...D 10 11 LED 11 12 LED 12 13 LED 13 14 LED 14 15 LED 15 Value 000 015 016 031 032 047 048 063 064 079 080 095 096 111 112 127 128 143 144 159 160 175 176 191 192 207 208 223 224 239 240 255 Description...

Страница 12: ...LED 14 15 LED 15 16 strobe 17 FADE Value 000 015 016 031 032 047 048 063 064 079 080 095 096 111 112 127 128 143 144 159 160 175 176 191 192 207 208 223 224 239 240 255 000 255 000 255 Description No...

Страница 13: ...control Strobe 00 20Hz 1 ON 2 ON 3 ON 1 ON 2 ON 3 ON 1 ON 2 ON 1 ON 3 ON 2 ON 3 ON 1 ON 2 ON 3 ON 1 OFF 2 OFF 3 OFF Convert to 11CH 2 No Function AUTO AT01 50 Auto speed Dimmer speed 11 channels 13 M...

Страница 14: ...ON Channel 8 provides individual control of the three LED modules in each fixture 245 255 switch to the 11CH 2 mode AUTO PROGRAMS Chanel 9 selects the preset Auto programs 1 50 When activating the Aut...

Страница 15: ...000 015 016 031 032 047 048 063 064 079 080 095 096 111 112 127 128 143 144 159 160 175 176 191 192 207 208 223 224 239 240 255 000 005 006 255 000 255 000 255 000 255 Description No Function R G B R...

Страница 16: ...LUE 0 100 WHITE 0 100 60 channels 16 Master Slave Control Mode 1 Setting master machine Access control panel function by pressing MODE until is displayed Press ENTER select by pressing UP DOWN buttons...

Страница 17: ...il COMP is displayed Press ENTER select C ID by pressing UP DOWN buttons Press ENTER Amount set of combined lights by pressing UP DOWN between 01 and 16 Press MODE to exit Att the number of the light...

Страница 18: ...3 224 239 240 255 000 005 006 255 000 005 006 255 000 009 010 255 000 255 000 244 245 255 000 005 006 255 000 255 000 255 Description No Function R G B R G G B R B R G B W R W G W B W R G W G B W R B...

Страница 19: ...in a short circuit In this event only the single LED which has failed will no longer function This does not mean that all of the LEDs have failed but the circuit is wired in series Note In the event o...

Страница 20: ...rol Panel settings for correct addressing Check DMX cables Check polarity switch settings on the controller Check cable connections Call service technician Note In the event of Display PCB failure a r...