4  SYSTEM INSTALLATION AND OPERATION:  

 

This part of the manual describes the installation and electrical connection of the XOLTA Compact BESS.

 

4.1  Delivery inspection

 

Each XOLTA Compact BESS system is delivered as a fully assembled cabinet. It has been carefully checked and 

 

tested prior to shipping. However, upon delivery, you should verify visually the state of packaging to make  

 

sure that it is in good condition. In case of any visible damage to the packaging, report it to XOLTA support.

 

•  The battery is intended to be wall mounted. The XOLTA Compact BESS must be placed vertically according  

 

  to installation guidelines and secured against slipping

 

•  The ambient temperature in the installation location can be in the range of −20

°C to +35°C; however, the  

 

  recommended ambient temperature to ensure the best battery performance and longevity is in the range  

 

  of +5°C to +25°C

 

4.2  Location requirements

 

•  The XOLTA Compact BESS is intended for indoor and outdoor use and is protected up to IP55 (Enclosure  

 

  Protection Rating for dust and water jets)

 

•  Install outdoor in a shaded location or on a north/north-east facing wall.

 

 

•  The battery should not be immersed in water or exposed to high temperatures, flames or physical force

 

•  No object should be placed on the top of the cabinet or within 0.5m of the top of the cabinet; free air  

 

  circulation should be ensured near to the battery heat sink

  

WARNING:

  

The XOLTA Compact BESS should not be installed at the following locations:

 

   

•  Areas prone to earthquakes

 

   

•  Altitudes more than 4000 meters above sea level

 

   

•  Areas prone to flooding, open flames, explosion and extreme changes of ambient temperatures

 

4.3 Installation procedure

 

The XOLTA Compact BESS is designed for connection to single or three phase 230V AC 50Hz electrical  

 

grids. However, the battery can also be connected to grids with other voltage levels if appropriate voltage/ 

 

powering units are in place (e.g. power transformers). Each XOLTA Compact BESS has the following installation  

 requirements:

 

•  1 P+N+PE 230V AC 50Hz power connection

 

•  Cabled internet connection

 

•  Single or three phase connection of auxiliary current transformers (CTs) for solar and household incoming  

 

  power monitoring

Содержание BAT-10

Страница 1: ...Advanced energy storage systems for solar system installations BATTERY SYSTEM MANUAL XOLTA COMPACT BAT 5 AND BAT 10 2021 by XOLTA ...

Страница 2: ... and BAT 10 8 2 2 XOLTA Compact BESS benefits 8 2 3 Maximizing consumption of solar power 8 2 4 Modularity and scalability of XOLTA BAT 5 and XOLTA BAT 10 9 2 5 Key specifications 10 3 XOLTA Battery Energy Storage System 3 1 Main features 11 3 2 Hardware description 12 3 3 Software description 13 4 System installation and operation 4 1 Delivery inspection 14 4 2 Location requirements 14 4 3 Instal...

Страница 3: ...ions or repairs undertaken by unqualified personnel or due to failure to follow the following important safety instructions The safety instructions have been divided into WARNING indicates a dangerous situation which if not avoided could result in injury or death CAUTION indicates a situation where damage to the equipment or injury may occur IMPORTANT SAFETY INSTRUCTIONS Read the entire document c...

Страница 4: ... inhaling the odor The XOLTA Compact BESS is heavy Suitable lifting equipment is strongly recommended Do not paint any part of the product Do not open the battery modules For long term storage longer than 1 month the battery should be charged to 40 charge and then disconnected from the grid When the product is to be disposed of follow all relevant local laws and regulations NOTE Failure to comply ...

Страница 5: ...eat and fire Hazardous fumes such as carbon dioxide carbon monoxide and hydrocarbons are emitted during battery fires ACTION Disconnect the power from the battery system at the electrical panel if possible without getting too close to the battery and without inhaling fumes Never try to extinguish a battery fire yourself If battery cells catch fire only qualified firefighting personnel with appropr...

Страница 6: ...ocedures described in this manual Furthermore we assume no responsibility for any infringements of rights of third parties which may result from the use of this manual Product modifications or changes to the product environment Only use the storage system in its original state without any unauthorized modifications and when it is in proper working order Safety devices must never be overridden bloc...

Страница 7: ... constantly out of service due to Purchaser for a period of more than six months after the initial installation The Covered Product has not been serviced properly and professionally or according to technical standards or the maintenance instructions of Covered Product The Covered Product has been exposed even temporarily to vibrations that not only insignificantly exceed the usual extent of vibrat...

Страница 8: ...nd commercial use The batteries are an essential enabler for the transition to renewable energy by balancing out volatile energy production with consumption The high energy density means little space is required on an outside wall to store sufficient electricity to power building consumption during peak tariff hours High performance is assured by 24 7 monitoring via an Internet connection which al...

Страница 9: ...ms can be connected on the AC side both on the same grid phase or the different grid phases The resulting battery power and energy capability are presented in Table 2 1 XOLTA BAT 5 and in Table 2 2 XOLTA BAT 10 Table 2 1 Battery power and energy for a different number of parallel connected XOLTA BAT 5 battery systems Table 2 2 Battery power and energy for a different number of parallel connected X...

Страница 10: ...rds UN38 3 classification for safe transportation EN 61010 1 2010 A1 2016 IEC 62619 2017 EN 61000 6 2 Industrial level EN 61000 6 4 Class A Region dependent and subject to service agreement TECHNICAL PROPERTIES 1 BATTERY Capacity 10 kWh Grid connection voltage 1 x 230V AC Ambient temperature rating 20 C to 35 C Cabinet design Various color and material choices Dimensions H 772mm x W 664 5mm x D 25...

Страница 11: ... can be connected and operated in parallel giving up to 10 8kW and 30kWh MULTIPURPOSE The battery is designed for various applications solar self consumption time shifting etc XOLTA CLOUD CONNECTION The battery is integrated with the XOLTA Cloud It allows for system monitoring control data acquisition and data storage SAFETY The battery is designed to offer exceptionally high operational safety For...

Страница 12: ... by a best in class battery management system BMS and battery protection unit BPU The BMS is responsible for monitoring protection and diagnostics of battery cells Battery cells and power conditioning units are thermally managed by a heat plate which is located on the back of the inverter There are three entry ports on the XOLTA Compact BESS Figure 3 2 Power entry port for electrical connection Et...

Страница 13: ...are of all the fast response requests from the grid It can ensure that the system operates safely without the internet connection and collects moderate amount of data as back up As shown in Figure 3 3 the Cloud is a bigger playground for all the data to drop in and to be processed for supporting further analytical functions such as monitoring alert economic summary forecasting advanced control alg...

Страница 14: ...p to IP55 Enclosure Protection Rating for dust and water jets Install outdoor in a shaded location or on a north north east facing wall The battery should not be immersed in water or exposed to high temperatures flames or physical force No object should be placed on the top of the cabinet or within 0 5m of the top of the cabinet free air circulation should be ensured near to the battery heat sink ...

Страница 15: ...roved electrician Any subsequent changes or modifications by unauthorized personnel are strictly prohibited and could compromise safety X 3 6kVA 5kWh 3 6kVA 10kWh L1 L2 L3 N PE Internet Cloud 1P N PE 230V House Loads PV inverter Energy meter Adapter Adapter Split core CTs Split core CTs Ethernet cable Voltage sensing Modbus RTU L1 L2 L3 N PE Internet Cloud Ethernet Switch House Loads PV inverter E...

Страница 16: ...ast 70 of initial battery capacity will be maintained The capacity is determined in amp hours Ah at a temperature of 25 C and a discharge rate of 0 2C rate from fully charged 100 SoC The warranty applies only if the battery system operating modes provided by XOLTA e g solar energy self consumption are used No other use of the battery is covered Currently the warranty is valid for the following cou...

Страница 17: ... monitor your battery you need to go to the XOLTA Web App and register your battery there Go to app xolta com For the best experience we recommend using the Google Chrome browser A step by step guide can be found in the document How to get started which is supplied with the battery For larger installations an API is available Contact support xolta com for details 2021 by XOLTA ...