- 18 -
�
�
�
�
�
Fig.7
2. CONNECT ELECTRICAL:
• Power Supply Connection:
For connection to the power supply refer to the following Fig.7:
1. Break and remove the small circular metal sheet positioned in the rear part of the hood,
with the aid of a flat screw driver Fig.7.1.
2. Remove the power supply lid by loosening the 2 screws A Fig.7.2.
3. Connect the wires of the hood to those of the power supply as described Fig.7.3:
BLACK = L line
WHITE = N neutral
GREEN / YELLOW = G ground
- A double-pole switch properly rated must be installed to provide the range hood
power supply disconnection.
- Connect the electrical conduit to the Field Wiring Compartment using listed onduit
fittings.
- Carry out the power supplly connection in accordance with the national electric
code, ANSI/NFPA 70-1999.
4. Insert the wires into the box, then close the box cover, securing it using the screws
that were previously removed.