• Power Supply Connection:

For connection to the power supply refer 

to the following 

Fig.4:

1.   Remove  the  power  supply  cover  by 

undoing the (2) screws 

Fig.4.

2.   Break  through  the  hole  on  the  box 

cover.

3.   Secure  the  power  supply  conduit  to 

the cover.

4.   Connect  the  wires  of  the  hood  to  tho-

se  of  the  power  supply  as  described. 

Fig.4:

BLACK

  = 

 L

 line

WHITE

  =  

N

 neutral

GREEN / YELLOW

 = 

 G

 ground

-  A  double-pole  switch  properly  rated 

must    be  installed  to  provide  the  range 

hood power supply disconnection.

-  Connect  the  electrical  conduit  to  the 

Field  Wiring  Compartment  using  listed 

conduit fittings.

- Carry out the power supplly connection 

in  accordance  with  the  national  electric 

code, ANSI/NFPA 70-1999.

5.   Insert  the  wires  into  the  box,  then 

close the box cover, securing it using 

the screws that were previously remo-

ved.

The  appliance  should  be  installed  at  a 

minimum height of 27” up to a maximum 

height  of  32”  for  optimal  performance. 

If  a  connection  ductwork  composed  of 

two  parts  is  used,  the  upper  part  must 

be placed outside the lower part. Do not 

connect the range hood exhaust duct air 

to the same duct air used to exhaust hot 

air or fumes from other appliances other 

than  electrical.  Before  proceeding  with 

the assembly operations, remove the an-

ti-grease filter(s) 

(Fig.5)

 so that the unit is 

easier to handle.

3. CONNECT THE DUCTWORK:

Содержание XOM30G

Страница 1: ...RA Manual de utilización USA F E XOM30G XOM36G NEED HELP Call our ventilation experts toll free al 800 966 8300 AVEZ VOUS BESOIN D AIDE Contactez nos experts au numéro gratuit 800 966 8300 NECESITA AYUDA Póngase en contacto con nuestros expertos a través del número gratis 800 966 8300 ...

Страница 2: ...iginal purchaser for products purchased for ordinary home use in North America Should you require service for your XO product call a product service specialist at 800 966 8300 Improper Installation Service trips to the home to teach you how to use the product Resetting circuit breakers Damage caused after delivery EXPECT MORE FROM XO When buying any XO appliance you can be confident you have purch...

Страница 3: ...s and vapors CAUTION To avoid motor bearing damage and noisy and or unbalanced impellers keep drywall spray construction dust etc off power unit CAUTION Please read specification label on product for further information and requirements WARNING TO REDUCETHE RISK OF FIRE ELECTRIC SHOCK OR INJURYTO PERSONS OBSERVE THE FOLLOWING A Use this unit only in the manner intended by the manufacturer If you h...

Страница 4: ...inguisher ONLY if 1 You know you have a Class ABC extinguisher and you already know how to operate it 2 The fire is small and contained in the area where it started 3 The fire department is being called 4 You can fight the fire with your back to an exit aBased on kitchen firesafety tips published by NFPA Proper maintenance of the Range Hood will assure proper performance of the unit INSTALLATION I...

Страница 5: ...s after a prolonged use of the appliance C No food must be cooked flambè underneath the hood D The use of an unprotected flame is dangerous for the filters and could cause fires E Watch constantly the fried food in order to avoid the cooking oil flares up F Before performing any mainteinance operation disconnect the hood from the elec trical service The manufacturers will not to accept any respons...

Страница 6: ...terruption of such naturally vented systems follow the heating equipment manu facturer s guidelines and safety standards such as those published by NFPA Duct Piece Dimensions Equivalent Number Length Quantity Used Total Equivalent Length Round straight 1 ft per foot lenhgth 3 1 4 x 10 straight 1 ft per foot lenhgth 90 elbow 12 ft 45 elbow 7 ft 3 1 4 x 10 3 1 4 x 12 90 elbow 14 ft 10 ft 3 1 4 x 10 ...

Страница 7: ...pe or Duct Tape INSTALL THE DUCTWORK NOTE To reduce the risk of fire use only metal ductwork 1 Decide where the ductwork will run between the hood and the outside 2 A straight short duct run will allow the hood to perform most efficiently 3 Long duct runs elbows and transitions will reduce the performance of the hood Use as few of them as possible 4 Install a roof or wall cap Connect 6 round metal...

Страница 8: ... 8 Hood Specifications Front of hood Side of hood Top of hood Mounting height and clearance Product dimensions and clearance XOM30G XOM36G ...

Страница 9: ...e appliance has been adjusted definitely fix the hood using the screws A Fig 2 For the vari ous installations use screws and screw anchors suited to the type of wall e g reinforced concrete plasterboard etc If the screws and screw anchors are pro vided with the product check that they are suitable for the type of wall on which the hood is to be fixed IMPORTANT The range hood must besecuredtowallst...

Страница 10: ...st be 2 wire with ground If the electrical supply does not meet the above requirements call a licensed electrician before proceeding Route house wiring as close to the installation location as possible in the ceiling or back wall Refer to Wiring Locations on page 11 Connect the hood wiring to the house wiring in accordance with local codes Grounding instructions The grounding conductor must be con...

Страница 11: ... as indicated in Fig 3 Before installing the appliance fix the electrical box as indicated in Fig 3 Fig 3B Lift the electrical plant box Fig 3D Position the electrical box so it is in line with the holes of the previously removed screws and tighten Fig 3A Remove the central screw Fig 3C Remove the 3 fixed screws Fig 3E Pay attention that the tear tape of the electrical box is inside the slot and t...

Страница 12: ...sing listed conduit fittings Carry out the power supplly connection in accordance with the national electric code ANSI NFPA 70 1999 5 Insert the wires into the box then close the box cover securing it using the screws that were previously remo ved The appliance should be installed at a minimum height of 27 up to a maximum height of 32 for optimal performance If a connection ductwork composed of tw...

Страница 13: ... bracket of the upper flue Fig 7 Then fix it to the ceiling using the screws A Fig 7 in such a way that it is in line with your hood and respecting the distance from the ceiling indicated in Fig 6 Connect the flange C to the air exhaust hole using a connection pipe Fig 8 Insert the upper flue into the lower flue Fix the lower flue to the hood using the screws B provided Fig 8 extract the upper flu...

Страница 14: ...e G Remove the two flues F G and place them on a flat surface Carbon filter kit XORFK01 The kit includes an air diverter A 2 screws and 2 expan sions plugs B and 2 rectangular filters C Fig 2 Make a mark on the wall and then drill a hole 1 4 inches away from the middle of the bracket Insert the expansion plug ...

Страница 15: ...er A and drill two holes as shown in the figure hole diameter 1 4 inches Once the two holes have been drilled fasten the air diverter A to the bracket H Fig 5 Fasten the air diverter permanently to the wall with a screw the hole previously drilled in Fig 2 Fig 6 Once the air diverter has been inserted into the bracket and fastened to the wall connect the flexible 6 Round Metal pipe to the diverter...

Страница 16: ...ue F to the bracket and fasten it using the 2 screws E Fig 8 Remove the aluminum panels by pulling the lever 1 out and pushing downwards 2 Fig 9 The charcoal fi lters C must be fit ted in the ducting unit located inside the hood Fig 10 Put the aluminum panels back in place Fig 8 ...

Страница 17: ...f and the LED of key F remains switched on with a fixed light until the motor starts up again at the first speed after fifty minutes and keys F and C start to flash again for ten minutes and so on By pressing any key for the exclusion of the hood light the hood will return immediately to its normal functioning e g if key D is pressed the clean air function is deactivated and the motor moves to the...

Страница 18: ... which is released back into the room The filters are not washable or re usable and must be replaced at least once every four months The active carbon filter saturation level depends on the frequency with which the appliance is used the type of cooking performed and the regularity with which the anti grease filters are cleaned Cleanthecookerhoodfrequently bothinsideandoutside usingaclothwhichhasbe...

Страница 19: ...ce causing rust DO NOT allow salt solutions disinfectants bleaches or cleaning compounds to remain in contact with stainless steel for extended periods Many of these compounds contain chemicals with may be harmful Rinse with water after exposure and wipe dry with a clean cloth Painted surfaces should be cleaned with warm water and mild detergent only ...

Страница 20: ...ssity it can be replaced only by special ized personnel Replacing halogen light bulbs To replace the halogen light bulbs B remove the glass panel C using a lever action on the relevant cracks Replace the bulbs with new ones of the same type Caution do not touch the light bulb with bare hands ...

Страница 21: ... 21 XOM30G XOM36G ...

Страница 22: ... 22 OPTIONS AND ACCESSORIES Model XORFK01 Ductless Recirculating Filter Kit Model XOEDCM Duct Cover Extension This accessory is available for installation with ceiling heights above 9ft to 10 ft ...

Страница 23: ...et 2 B 1 8 x 6 8 Screws for attaching the decorative flue to the mounting bracket 6 Duct bracket Aluminum filter 2 piece decorative duct cover dimension shown for reference only INSTALLATION PREPARATION Check installation hardware Locate the hardware package packed with the hood and check contents ...

Страница 24: ...e cleaning Mounting Height from cooking surface 27 32 Duct Options and Electrical Requirements 6 inch duct required Ductless Option for applications where no ducting in available AC 120v 60Hz 4 35amp Options Optionalductcoverextensionisavailableforceiling heights up to 10 ft tall Model XOEDCM Optional recirculating kit if outside venting is unavailable Model XORFK01 XO is Exclusively Distributed b...

Отзывы: