- 1
2
-
30” to 42”
NON-COMBUSTIBLE
BACKSPLASH
We recommend oversizing the hood by 3" on
each side to maximize efficiency and capture
space
For example;
A 36" Grill would require a 42" Hood
OVERHEAD CONSTRUCTION
REAR
WA
LL
60”
Minimum above
cooking surface to
non-combustible
overhead.
highs and lows
All range hoods have a recommended range of installation height over the cooking
surface.
It is important to install the hood at the proper mounting height. Hoods mounted too
low could result in heat damage and fire hazard; while hoods mounted too high will
be hard to reach and will lose its performance and efficiency.
IMPORTANT
: This range hood is intended for covered patios or terraces. This
unit must protected from the effects of weather. The ro
o
f cap and the wall cap
must be considered to prevent
water
from
entering
. Once installed, it must be
sealed to prevent leaks.