background image

    

Failure To Follow All Electrical Safety Measures May Result in Serious Injury, 

Fire Or Death

All electrical work should only be performed by an

experienced, licensed electrician.

All XO units MUST be grounded for safe operation

 and

come equipped with a

  3 Prong molded cord/plug for that 

purpose.

NEVER remove or disable the 3rd prong with an adapter.

NEVER use an extension cord to operate your XO unit.

Your XO unit is built to operate on 115V 60Hz and 

should be plugged directly into a dedicated 15 amp

3 prong outlet.  If you are uncertain as to the 

voltage, amperage capacity or if the 3rd prong is

properly grounded - consult a licensed electrician.

To maximize the depth of the installation recess - 

your outlet should be mounted flush with the wall.

Your XO unit should not share the circuit with any other

electrical devices as this may cause overloading, 

overheating, blown fuses or tripping circuit breakers.  

In a worst case this can pose a fire hazard.

NEVER handle your XO unit in wet conditions as this 

can pose a severe danger of electric shock.

Exercise care when moving your XO unit to avoid 

damage to the electrical cord.  If the electrical cord of 

your XO unit becomes worn or damaged it must be 

replaced immediately by a qualified technician.

NEVER unplug your unit by pulling on the cord. 

Unplug by gripping the plug firmly and pull out 

straight from the outlet.

    

INDOOR USE ONLY:

This model is intended for indoor/interior 

applications only and is not to be used in 

installations that are open/exposed to natural 

elements.

This unit is designed to operate between 60  F and 

90  F.  Higher ambient temperatures may reduce

the unit’s ability to reach low temperatures and/or

reduce performance.

For best performance, keep the unit out of direct 

sunlight and away from heat generating equipment.

In climates where high humidity and dew points are

present, condensation may appear on outside surfaces,

particularly in non air conditioned spaces.

This is considered normal. The condensation will

evaporate when the humidity drops.

CAUTION

Damages caused by ambient extremes are not 

covered by the warranty

  

SERVICE 

115V - 60 Hz - 1 phase

AMPS   

15 Amp Circuit Breaker

Requires a Dedicated Outlet
All electrical work must be performed by
a licensed electrician

7

Serious injury, fire or death...
Okay - 

o

o

Содержание U24WDZGO

Страница 1: ...I worked really hard on this manual so please read it XOU24WDZGO PANEL READY 2 ZONE WINE COOLER WATCH THE INSTALLATION VIDEO ON OUR CHANNEL...

Страница 2: ...u can be confident you have chosen a high quality innovative and stylish product from a company that cares about you If you require service or have questions Help is only a phone call away call 973 40...

Страница 3: ...ce Warranty 4 7 Installation Instructions Sizes and Installation Dimensions Leveling Your XO 8 13 21 22 23 24 3 where things are please read and follow all safety instructions It s for your own good H...

Страница 4: ...ly inspected all surfaces for any imperfections Have you reviewed this manual with the customer and explained the unit s operation and care Has the customer received copies of the literature and keys...

Страница 5: ...5 XOU24WDZGOR XOU24WDZGOL WINE COOLERS 2 these are the models covered in this book take a minute to circle your model above and record your serial number here in case you need it later...

Страница 6: ...Failure to follow this step may cause problems Location Your XO unit should be located away from direct sunlight and heat sources stove heaters etc which may increase electrical consumption High or lo...

Страница 7: ...c shock Exercise care when moving your XO unit to avoid damage to the electrical cord If the electrical cord of your XO unit becomes worn or damaged it must be replaced immediately by a qualified tech...

Страница 8: ...ITS ARRIVE PRE WIRED WITH LOW PROFILE PLUGS FOR EASY INSTALLATION 34 1 4 MIN 24 90 Door Swing WALL Clearance Gap IF THE DOOR CAN T OPEN FULLY YOU CAN T PULL THE SHELVES OUT WHEN INSTALLING WITH THE HI...

Страница 9: ...AY DOORS depth CUSTOM OVERLAY PANELS MAY ADD UP TO 3 4 IN OVERALL DEPTH YOUR CHOICE OF CABINET HANDLES WILL ALSO ADD DEPTH 90o 110o 140o DOOR MUST BE ABLE TO OPEN 90 MINIMUM TO ALLOW SHELVES TO EXTEND...

Страница 10: ...t least 5 16 in diameter and 1 deep into the top and bottom of the frame in the location shown TO ACCOMMODATE THE HINGE PINS ON THE HINGE SIDE OF THE PANEL 2 7 8 73mm min 5 127mm max IF FRAME HEIGHT E...

Страница 11: ...einstall it shortly In the channel are 10 screw holes 5 Attach your door handle to the frame countersinking the screw heads so the frame lays at against the door 6 Align the frame to the door If the f...

Страница 12: ...the two screws removed in Step 1 ADJUSTMENT SCREWS TOP BOTTOM If the door requires adjustment the top and bottom hinge each have adjustment screws Loosen the screws then with the door open raise the...

Страница 13: ...ners until all four legs are seated firmly on the floor and the interior floor of the unit is level both front to back and side to side Failure to follow this important step may cause problems with pr...

Страница 14: ...re usually normal Sounds can also be ampli ed by hard surfaces like ooring or tiles Here is a description of the types of sounds you might hear and what might be causing them may run longer than your...

Страница 15: ...out of direct sunlight to limit both UV and heat exposure VIBRATION Vibration is another element that can harm wine Your XO Wine Cooler has design features to aid in limiting the transmission of vibra...

Страница 16: ...ing the compartment temperature To view the real time temperature press and hold the button for 5 seconds The interior temperature will flash in the LED Display for 5 seconds If you wish to change the...

Страница 17: ...pliance will operate however it will not respond to your actions To initiate Sabbath Mode Press and hold both for 5 seconds The display will show either Sb or Sb On depending on the model you have to...

Страница 18: ...Functions L1 L2 L3 TEMPERATURE DISPLAYS UPPER LOWER Indicator Light Cooling Mode ON Press to raise temperature Press to lower temperature Changes interior light color Toggles between different operati...

Страница 19: ...f 7 5 Racks of 7 35 6 l 5 u 35 6 l 5 u 24 2 MODEL WIDTH ZONES BORDEAUX BURGUNDY 46 TOTAL 46 TOTAL Shelf capacities Store wine in sealed bottles only Avoid overloading Storing little or no product can...

Страница 20: ...rack STEP 2 Remove and re position the rack glides STEP 3 Reverse the steps LIFT THE FRONT PULL OUT STRAIGHT Install the right and left RACK GLIDES in their new position by pushing the pins into the s...

Страница 21: ...the wine cooler power failure Most power failures are corrected within a few hours and should not affect the temperature of your appliance if you minimize the number of times the door is opened If the...

Страница 22: ...straight out to remove Align the tabs and insert the new filter Rotate filter 1 4 turn to lock in place Your Air Refresh Charcoal Filter I P N XOUAIRFILTER s Located Here 22 a breathe of fresh air fo...

Страница 23: ...you have not recently added a large quantity of warm bottles it may be a mechanical issue Unplug the unit and call for service The alarm is beeping and LO is displayed on the control panel This may be...

Страница 24: ...e obligations other than those expressly covered by this warranty Open box factory seconds scratch and dent floor models and commercial applications are excluded from these warranties Consumer shall b...

Отзывы: