Xo ODONTOSURGE Скачать руководство пользователя страница 17

L.

WARRANTY

For the XO ODONTOSURGE, XO CARE A/S grants a warranty of 12 months as from the
date of the Contract of Sale and in accordance with terms and conditions defined on the
Guarantee Card going with each unit.

Defects proven to be caused by failure of materials, construction or manufacturing will be
repaired free of charge.  Any further liability is explicitly declined.

The warranty does not apply to normal wear or to damage resulting from accident, abnormal
use, misuse, abuse or neglect.

Guarantee repairs or replacements will only be carried out upon receipt of the defect unit
together with its Guarantee Card.

Responsibility as to the safety, reliability and performance of the XO ODONTOSURGE will
not be accepted by XO CARE A/S:

a. If the equipment has not been used under normal conditions for its intended purposes

and in strict accordance with this manual and/or

b. if any technical changes including repairs, adjustments/calibrations and reconstructions

have been made by anyone other than XO CARE A/S or specialists approved by XO
CARE A/S.

The purchaser assumes all risks and liabilities resulting from the use of the XO
ODONTOSURGE, whether used separately or in combination with other products not manu-
factured by XO CARE A/S.

XO CARE A/S continually strives to improve its products and therefor reserves the right to
improve, modify or discontinue products at any time, and to change the specifications with-
out notice and without incurring obligations.

15

Содержание ODONTOSURGE

Страница 1: ...XO CAREA S Usser d M lle H ndv rkersvinget 6 DK 2970 H rsholm Denmark tel 45 70 20 55 11 fax 45 70 20 55 10 www xo care com XO ODONTOSURGE Instruction Manual YA 551 vers 1 00...

Страница 2: ...followed in order to enhance safety and effectiveness In particular for those with little or no experience with HF Soft Tissue Handling and also for those familiar with conventional low frequency uni...

Страница 3: ...N OFF Finger Switch 6 E How to Operate 7 F Preparation and Familiarization 9 F1 Dissection Exercise 9 F2 Coagulation Exercise 9 F3 GeneralAdvice 9 G Clinical Application 11 G1 Contraindications to HF...

Страница 4: ...OSURGE 1 Instrument socket 5 Handpiece holder 9 Mains power cord 2 ON OFF finger switch 6 Mode switch panel for instrument activation 3 Handpiece detachable 7 Seven instruments in holder casing 4 Hand...

Страница 5: ...10 green lamp 11 blue lamp 12 yellow lamp COAG CUT 13 Handpiece cord 15 Mains power inlet 17 Fuse drawer connector 14 Warning symbol 16 Main ON OFF switch see chapter M 3...

Страница 6: ...tral role for the completely automatic and instantly re sponding power tuning system of the XO ODONTOSURGE As a result the unique power tuning system is continuously controlling and precisely adapting...

Страница 7: ...the handpiece holder by inserting its tongue into the slot in the side of the control box left or right side at option C3 Control Box 1 Check that your unit is correctly rated for your local power lin...

Страница 8: ...ady to operate Blue lamp OFF means standby mode ST BY mode with handpiece inoperative CUT switch Turns yellow lamp on and off Yellow lamp ON means cutting mode CUT mode with handpiece ready to operate...

Страница 9: ...ment is now ready for operation Activate the instrument by pressing and holding the ON OFF finger switch on the handpiece Note the acoustic signal for cutting Coagulation haemostasis 1 As a first step...

Страница 10: ...N OFF finger switch responds with an acoustic signal Do not touch the instrument when the acoustic signal is sounding CAUTION Always switch to standby mode only green lamp on as soon as the treatment...

Страница 11: ...not be dry If it is moisten lightly with water 5 Hold the handpiece in a pencil type grip and hold the instrument in position slightly above the tissue surface Activate the instrument by pressing and...

Страница 12: ...essing and holding the ON OFF finger switch The acoustic signal for the COAG mode will now be heard 4 Make repeated taps with the activated instrument on the tissue This will result in small target ar...

Страница 13: ...rative dentistry will greatly benefit from your use of the XO ODONTOSURGE Special instructions are available upon request G1 Contraindications to HF Soft Tissue Handling 1 HF Soft Tissue Handling is c...

Страница 14: ...o autoclave the instruments between pa tients The instruments can be sterilized by steam autoclaving maximum temperature 135 C 271 F conveniently when placed in the holder casing with opened or remove...

Страница 15: ...accordance with this Manual The XO ODONTOSURGE and its accessories must not be taken into use if signs of operational electrical or mechanical defects are found The XO ODONTOSURGE must not be taken in...

Страница 16: ...M D D 93 42 EEC Primary fuses For mains voltage 100 and 115V 2 00 amp time lag For mains voltage 230V 0 80 amp Generator frequency 27 MHz Max output power 50 watts at non inductive load impedance of 5...

Страница 17: ...s to the safety reliability and performance of the XO ODONTOSURGE will not be accepted by XO CARE A S a If the equipment has not been used under normal conditions for its intended purposes and in stri...

Страница 18: ...s whether they are in the form of an anesthetic or skin preparation agent are produced by natural processes within body cavities or originate in surgical drapes tracheal tubes or other materials 3 The...

Страница 19: ...o a serious deterioriation of the state of health of a patient or user In the improbable event that your XO ODONTOSURGE should be involved in such an inci dent it is therefore very important that you...