18
• smoke or use a naked flame when handling fuel
• keep fuel in a space that is not designed for such purpose. If
the boat is not equipped with a heater, a spare fuel tank can be
stored in place of the heater's tank.
• leave the boat unattended when a cooker or heater is in use.
5.8 ELECTRICAL SYSTEM
The boat's wiring diagram is shown in Appendix 3. The main switch
is located on the port side, under the aft sofa. However, the automa-
tic bilge pump is always operational when the battery is connected.
When the circuit is closed, the various devices can be operated with
the switch panel at the helm station.
The navigation lights are switched on with the running light switch
(see Figure 5). Remember to install the removable mast light in
position. The boat's windscreen wiper is operated with appropriate
switch. To check the amount of bilge water, activate the bilge pump
with its switch (see Figure 5). If you cannot hear the sound of water
flowing beside the boat at the stern, the automatic system has
drained the water properly.
The electrical system is pre-fitted for adding various optional equip-
ment, and is fully fitted for adding a radio/CD player and two spea-
kers.
The layout of controls and electrical equipment is shown in Figures
4 and 5. The fuses for electrical circuits are located in a separate
fuse panel inside the helm console (see Figure 4). The XO boats are
equipped with automatic fuses. If such a fuse is tripped as a result
of overload, you can easily reset it by pushing down the fuse but-
ton that has popped up. The electrical system has two additional
circuits, ‘Extra 1’ (10 A) and ‘Extra 2’ (10 A) (wiring diagram posi-
tions F13-F14 and F17-F19). These circuits are protected with fuses
and are designed for connecting retrofitted optional equipment. The
wires for these circuits can be found in the switch panel. Do not rep-
lace the fuses with fuses that have higher current ratings, and do
not add components to the electrical system so that the circuit's
nominal amperage rating is exceeded.
Zinc anodes are installed on the transom. Replace the anodes when
they are over 50% of their original size.
WARNING!
Never use the hull for earthing. both the negative and positive
sides of all electrical installations must be insulated from the hull.
Содержание 200 S CC
Страница 1: ......
Страница 2: ...w w w xoboats fi...
Страница 4: ...4...
Страница 6: ...6...
Страница 8: ...8...
Страница 10: ...10...
Страница 25: ...25 Working decks and bathing ladder Figure 6 Bathing ladder Working decks...
Страница 31: ...31...
Страница 46: ...46 XO Boats Oy www xoboats fi info xoboats fi RANTALINNA RANTAKATU FI 65100 VAASA FINLAND...