Instruction manual NXT200/250 AC/DC page 9
Reset
It is possible to recall all factory standard
parameters. In this case the program of the machine
will be TIG AC, 2-times, HF with the following
parameters:
•
MMA current 80A
•
TIG Current 80A
•
TIG Spot Current 80A
•
Pre-flow 0.2 sec
•
Post-flow 3.0 sec
•
No
slope-up/slope-down
•
Start amp 40%
•
Stop amp 20%
•
Second Current level 50%
•
Base amp 50%
•
Fast pulse frequency 100Hz
•
Pause time = Pulse time = 0.1 sec
•
Penetration (TIG AC) 65%
•
Electrode Pre-heating (TIG AC) 11
The Reset procedure is as follows:
Switch off the machine and wait until display is
extinguished.
Press the following key pads
simultaneously:
Switch on the machine and keep the
above keys pressed until the display
shows “80”. Then release the keys.
.