![XNET IGC2050F Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/xnet/igc2050f/igc2050f_install-manual_3537600009.webp)
9 /
17
X
X
N
N
E
E
T
T
N
N
e
e
t
t
w
w
o
o
r
r
k
k
B
B
o
o
x
x
C
C
a
a
m
m
e
e
r
r
a
a
I
I
n
n
s
s
t
t
a
a
l
l
l
l
G
G
u
u
i
i
d
d
e
e
2
2
.
.
3
3
.
.
3
3
C
C
o
o
n
n
n
n
e
e
c
c
t
t
i
i
n
n
g
g
t
t
o
o
A
A
l
l
a
a
r
r
m
m
d
d
e
e
v
v
i
i
c
c
e
e
s
s
z
Alarm Input
Wires from various sensor type (IR, heat, and magnetic) can be connected to Alarm in(+)/(-) terminal as
shown in figure 2.5. (NC or NO of sensor input can be selected at Menu screen.)
Alarm Sensor device requires a separate power source.
Figure 2-5. Connecting to Alarm Input
z
Alarm Output
This terminal can only be connected up to AC 30V/400mA or DC 30V/400mA. An additional relay device
has to be used to control higher voltage or current.
Internal Circuitry External Circuitry
Figure 2-6. Connecting to Alarm Output