Technical Support US: 888-443-2751
Technical Support INTL: 316-943-2751
16
OVEN ELECTRICAL REQUIREMENTS
FOR EACH OVEN:
A separate circuit breaker must be provided for each oven deck
Electrical connections must be accessible when the ovens are in the installed position
Electrical connections must meet all local code requirements
Ensure ovens are grounded per local codes
208
208
30
60
1
6
220/240
220/240
30
60
1
6
3 Wire Service - L1, L2
+1 Ground (per oven)
Electric Oven Electrical Requirements
Per EACH Oven
Oven Model
Volts AC
Amps
Hertz
Phase
KW
OVEN RECEPTACLE
Each countertop oven will need a wall receptacle. The connector provided with the oven is
a NEMA 6-50P 3 Prong plug.
NOTE
The power cord supplied with the countertop oven has a length of 72in/1828mm.
Ensure that the power cord may be connected to the receptacle without strain, possi-
bility of abrasions, or any damage to the prongs or insulation when determining the
placement of the oven.
Содержание 1620
Страница 11: ...Technical Support US 888 443 2751 Technical Support INTL 316 943 2751 11 This page intentionally left blank ...
Страница 21: ...Technical Support US 888 443 2751 Technical Support INTL 316 943 2751 21 OVEN ASSEMBLY Install Conveyor 1 2 3 ...
Страница 32: ...Technical Support US 888 443 2751 Technical Support INTL 316 943 2751 32 OVEN CLEANING 6 7 8 ...
Страница 41: ...Technical Support US 888 443 2751 Technical Support INTL 316 943 2751 41 This page intentionally left blank ...
Страница 44: ...Technical Support US 888 443 2751 Technical Support INTL 316 943 2751 44 This page is intentionally left blank ...
Страница 45: ...Technical Support US 888 443 2751 Technical Support INTL 316 943 2751 45 NOTES ...