Xirrus XR-1000H Series Скачать руководство пользователя страница 26

XR-1000H Quick Installation Guide 

 

- 22 -

 

Only

 

antennas

 

provided

 

by

 

Xirrus

 

for

 

use

 

with

 

the

 

product

 

should

 

be

 

installed.

 

The

 

use

 

of

 

any

 

other

 

antennas

 

may

 

cause

 

damage

 

to

 

the

 

access

 

points

 

or

 

violate

 

regulatory

 

emission

 

limits

 

and

 

will

 

not

 

be

 

supported

 

by

 

Xirrus.

 

International Guidelines for Exposure to Radio Waves 

The

 

Xirrus

 

Arrays

 

include

  

radio

 

transmitters

 

and

 

receivers.

 

It

 

is

 

designed

 

not

 

to

 

exceed

 

the

 

limits

 

for

 

exposure

 

to

 

radio

 

waves

 

(radio

 

frequency

 

electromagnetic

 

fields)

 

recommended

 

by

 

international

 

guidelines.

 

The

 

guidelines

 

were

 

developed

 

by

 

an

 

independent

 

scientific

 

organization

 

(ICNIRP)

 

and

 

include

 

a

 

substantial

 

safety

 

margin

 

designed

 

to

 

ensure

 

the

 

safety

 

of

 

all

 

persons,

 

regardless

 

of

 

age

 

and

 

health.

 

As

 

such

 

the

 

systems

 

are

 

designed

 

to

 

be

 

operated

 

as

 

to

 

avoid

 

contact

 

with

 

the

 

antennas

 

by

 

the

 

end

 

user.

 

It

 

is

 

recommended

 

to

 

set

 

the

 

system

 

in

 

a

 

location

 

where

 

the

 

antennas

 

can

 

remain

 

at

 

least

 

a

 

minimum

 

distance

 

as

 

specified

 

from

 

the

 

user

 

in

 

accordance

 

to

 

the

 

regulatory

 

guidelines

 

which

 

are

 

designed

 

to

 

reduce

 

the

 

overall

 

exposure

 

of

 

the

 

user

 

or

 

operator.

 

Separation Distance

MPE Distance 

Limit

0.79 mW/cm

2

 

17.79 cm (7 inches) 

1.00 mW/cm

2

 

The

 

World

 

Health

 

Organization

 

has

 

stated

 

that

 

present

 

scientific

 

information

 

does

 

not

 

indicate

 

the

 

need

 

for

 

any

 

special

 

precautions

 

for

 

the

 

use

 

of

 

wireless

 

devices.

 

They

 

recommend

 

that

 

if

 

you

 

are

 

interested

 

in

 

further

 

reducing

 

your

 

exposure

 

then

 

you

 

can

 

easily

 

do

 

so

 

by

 

reorienting

 

antennas

 

away

 

from

 

the

 

user

 

or

 

placing

 

he

 

antennas

 

at

 

a

 

greater

 

separation

 

distance

 

then

 

recommended.

 

FCC Guidelines for Exposure to Radio Waves 

The

 

1550

 

series

 

device

 

includes

 

a

 

radio

 

transmitter

 

and

 

receiver.

 

It

 

is

 

designed

 

not

 

to

 

exceed

 

the

 

limits

 

for

 

exposure

 

to

 

radio

 

waves

 

(radio

 

frequency

 

electromagnetic

 

fields)

 

as

 

referenced

 

in

 

FCC

 

Part

 

1.1310.

 

The

 

guidelines

 

are

 

based

 

on

 

IEEE

 

ANSI

 

C

 

95.1

 

(92)

 

and

 

include

 

a

 

substantial

 

safety

 

margin

 

designed

 

to

 

ensure

 

the

 

safety

 

of

 

all

 

persons,

 

regardless

 

of

 

age

 

and

 

health.

 

As

 

such

 

the

 

systems

 

are

 

designed

 

to

 

be

 

operated

 

as

 

to

 

avoid

 

contact

 

with

 

the

 

antennas

 

by

 

the

 

end

 

user.

 

It

 

is

 

recommended

 

to

 

set

 

the

 

system

 

in

 

a

 

location

 

where

 

the

 

antennas

 

can

 

remain

 

at

 

least

 

a

 

minimum

 

distance

 

as

 

specified

 

from

 

the

 

user

 

in

 

accordance

 

to

 

the

 

regulatory

 

guidelines

 

which

 

are

 

designed

 

to

 

reduce

 

the

 

overall

 

exposure

 

of

 

the

 

user

 

or

 

operator.

 

The

 

device

 

has

 

been

 

tested

 

and

 

found

 

compliant

 

with

 

the

 

applicable

 

regulations

 

as

 

part

 

of

 

the

 

radio

 

certification

 

process.

 

Separation Distance

MPE Distance 

Limit

0.79 mW/cm

2

 

17.79 cm (7 inches) 

1.00 mW/cm

2

 

The

 

US

 

Food

 

and

 

Drug

 

Administration

 

has

 

stated

 

that

 

present

 

scientific

 

information

 

does

 

not

 

indicate

 

the

 

need

 

for

 

any

 

special

 

precautions

 

for

 

the

 

use

 

of

 

wireless

 

devices.

 

The

 

FCC

 

Содержание XR-1000H Series

Страница 1: ...Quick Installation Guide for XR 1000H Series Wireless Arrays November 2012 ...

Страница 2: ...ll other trademarks and brand names are marks of their respective holders All rights reserved This document may not be reproduced or disclosed in whole or in part by any means without the written consent of Xirrus Inc Document Part Number 812 0085 003 Revision B November 2012 ...

Страница 3: ...l 6 9 Connect the Cables 7 10 Log In to the Array 8 11 Configure the Array 9 12 Secure Low Level Access to the Array 10 Drawings 11 XR 1230H Dimensions 11 Mounting Bracket Dimensions 12 Customer Support 12 Notices Warnings Compliance Statements 12 Notices 12 Warnings 14 WiFi Alliance Certification 15 Federal Communications Commission FCC Statements Instructions 15 Industry Canada Statements and Wa...

Страница 4: ...XR 1000H Quick Installation Guide ii ...

Страница 5: ...ed via Power over Gigabit Ethernet PoGE using an Ethernet Cat 5e or Cat 6 cable that also carries data traffic You must provide a network connection and Ethernet cable run from a Xirrus PoGE Power Injector port for the Array Gigabit port The Xirrus PoGE Power Injector requires an AC outlet Use only Xirrus supplied PoGE injectors See the PoGE Installation Guide for more information XR 1000H Arrays ...

Страница 6: ...h ground point is not available consult an electrician to have one installed Crimp a terminal lug to a sufficient length of 16 gauge wire to reach from the mounted Array to the earth ground point Before the Array is attached to a wall or pole secure the terminal lug to the Array with the 6 screw provided in the location shown 4 Install the Mounting Plate The accessory kit includes a small mounting...

Страница 7: ...for additional contact information Complete the following steps to mount the Array to a pole Install the metal bands through the holes in the mounting bracket Hand tighten the Band It strap through the pole mounting bracket thread it through the strap buckle and then bend the strap back Using the Band It tool place the tool onto the strap Rotate the Band It tool so that it can pull the excess stra...

Страница 8: ...strap Your installation should now appear as shown here Using a hammer bend back and flatten the remaining strap Using a hammer bend and flatten the two tabs on the buckle so that they hold the flattened strap end in place The completed attachment should have the mounting bracket firmly seated against the pole One band should be enough for most installations however a second band can be used for a...

Страница 9: ...applied Contact the appropriate electrical inspection authority or an electrician if you are uncertain that suitable grounding is available Part of the mechanical installation is to insure that the Array is grounded to earth ground to dissipate any static electric charge that may develop due to wind In Step 3 you secured a terminal lug to the Array with the provided 6 screw see Step 3 if this has ...

Страница 10: ...d 3 x 3 omni directional antenna Part M6060060MO1D33607 Manufacturer Terrawave Solutions www terrawave com 2 4 5 8GHz Dual Polarized Panel Antenna Part ANT DIR MIMO 01 Description 14dBi dual band polarized 3 x 3 panel antenna Part HG2458 14DP 3NF Manufacturer L COM Inc WWW L COM COM The MIMO Omnidirectional antenna includes an L Bracket for mast or wall mounting The Dual Polarized Panel antenna is...

Страница 11: ... POE port Only Xirrus supplied power injectors may be used Data Data is supplied to the Gigabit port via the same cable that powers the Array Connect the Ethernet cable carrying data and power from the PoGE injector to the Array s GIG POE port as indicated The following illustration shows a typical pole mounted XR 1000H installation after the antenna is installed and cable attachments have been co...

Страница 12: ...its subnet mask to 255 255 255 0 If this subnet is already in use on your network you may connect your computer directly to the Array by connecting the computer to the power injector s IN port temporarily this port may be called the SWITCH port or the DATA port on your injector If the assigned IP address is unknown you may use the Xirrus Xircon utility to communicate with any XR 1000 on the local ...

Страница 13: ...ou in an email as an attachment in the form of an Excel file xls Enter the key exactly as it appears in the file Click the Apply button In the Admin Settings section change both the default admin username and password to improve Array security Enter New Admin User and New Admin Password then Confirm Admin Password Leave New Admin Privilege Level at read write Click Apply Admin Settings when done B...

Страница 14: ...has its own username and password separate from the ArrayOS Admin User and Password used for logging in to the WMI and CLI Xirrus also provides the Xircon utility for connecting to Arrays that are not reachable via the normal access methods such as Secure Shell SSH or WMI and that do not have a physical console port XR 1000 or whose console port is not accessible Xircon discovers Arrays on your ne...

Страница 15: ...fault values of admin admin In the example below replace newusername and newpassword with your desired entries Note that these entries are case sensitive config boot env set username newusername config boot env set password newpassword config save 3 It is possible to change Xircon access permission to allow Xircon to access the Array at the CLI level only or at the XBL level only See the Xircon Us...

Страница 16: ...or 1 805 262 1600 Direct Europe Middle East and Africa 44 20 3239 8644 Australia 1 300 XIRRUS 1300 947 787 Local Call Cost Asia and Oceania 61 2 8006 0622 Latin Central and South America 1 805 262 1600 Notices Warnings Compliance Statements Notices Read all user documentation before powering this device Please verify the integrity of the system ground prior to installing Xirrus equipment Additiona...

Страница 17: ...receivers that enables maximum ratio combining MRC The 5 GHz a n radio operates in the UNII 2 band 5 25 5 35 GHz UNII 2 Extended ETSI band 5 47 5 725 GHz and the upper ISM band 5 725 5 850 GHz It has two transmitters with a maximum total output power of 26 dBm for UNII 2 and Extended ETSI bands for the A domain The total maximum output power for the upper ISM band is 28 dBm for A domain Power sett...

Страница 18: ...een modified to be especially qualified for such use CAUTION The liquid tight adapters must be used on all input output connections to the Array where the installation is a non hazardous location and conduit is not used POWER WARNING Read the installation instructions before connecting the system to the power source WARNING Installation of the equipment must comply with local and national electric...

Страница 19: ... the 5 GHz band Antennas having a gain greater than 6 dB are strictly prohibited for use with this device The required antenna impedance is 50 ohms To reduce potential radio interference to other users the antenna type and its gain should be so chosen that the equivalent isotropically radiated power EIRP is not more than that permitted for successful communication WiFi Alliance Certification Feder...

Страница 20: ... of a TDWR location shall be separated by at least 30 MHz center to center from the TDWR operating frequency as shown in the TDWR location at http www spectrumbridge com udia home aspx This will require that channel 116 is not used in these locations The installers and the operators must register the devices in the industry sponsored database with the appropriate information regarding the location...

Страница 21: ...ion is subject to the following two conditions 1 this device may not cause interference and 2 this device must accept any interference including interference that may cause undesired operation of the device Le présent appareil est conforme aux CNR dʹIndustrie Canada applicables aux appareils radio exempts de licence Lʹexploitation est autorisée aux deux conditions suivantes 1 lʹappareil ne doit pa...

Страница 22: ...he regulatory requirements Declaration of Conformity Cesky Czech Toto zahzeni je v souladu se základnimi požadavky a ostatnimi odpovidajcimi ustano veni mi Směrnice 1999 5 EC Dansk Danish Dette udstyr er i overensstemmelse med de væsentlige krav og andre relevante bestemmelser i Direktiv 1999 5 EF Deutsch German Dieses Gerat entspricht den grundlegenden Anforderungen und den weiteren entsprechende...

Страница 23: ...lony mi Dyrektywą UE 1999 5 EC Portuguès Portuguese Este equipamento está em conformidade com os requisitos essenciais e outras provisões relevantes da Directiva 1999 5 EC Slovensko Slovenian Ta naprava je skladna z bistvenimi zahtevami in ostalimi relevantnimi popoji Direktive 1999 5 EC Slovensky Slovak Toto zariadenie je v zhode so základnými požadavkami a inými prislušnými nariadeniami direktiv...

Страница 24: ...ntry may change at any time Xirrus recommends that you check with local authorities for the current status of their national regulations for both 2 4 GHz and 5 GHz wireless LANs The following countries have additional requirements or restrictions than those listed in the above table Belgium The Belgian Institute for Postal Services and Telecommunications BIPT must be notified of any outdoor wirele...

Страница 25: ...Xirrus Array products are designed to comply with the following national and international standards on Human Exposure to Radio Frequencies US 47 Code of Federal Regulations Part 2 Subpart J American National Standards Institute ANSI Institute of Electrical and Electronic Engineers IEEE C 95 1 99 International Commission on Non Ionizing Radiation Protection ICNIRP 98 Ministry of Health Canada Safe...

Страница 26: ...cate the need for any special precautions for the use of wireless devices They recommend that if you are interested in further reducing your exposure then you can easily do so by reorienting antennas away from the user or placing he antennas at a greater separation distance then recommended FCC Guidelines for Exposure to Radio Waves The 1550 series device includes a radio transmitter and receiver ...

Страница 27: ...fic information does not indicate the need for any special precautions for the use of wireless devices They recommend that if you are interested in further reducing your exposure you can easily do so by reorienting antennas away from the user placing the antennas at a greater separation distance than recommended or lowering the transmitter power output Additional Information on RF Exposure You can...

Страница 28: ...roduct means a multi radio access point containing four or more distinct radios capable of simultaneous operation on four or more non overlapping channels 1 4 Software means collectively each of the application and embedded software programs delivered to Customer in connection with this Agreement For purposes of this Agreement the term Software shall be deemed to include any and all Documentation ...

Страница 29: ...ftware or code used by Customer iii allow access to the Software by any user other than by Customerʹs employees and contractors who are bound in writing to confidentiality and non use restrictions at least as protective as those set forth herein iv except as expressly set forth herein write or develop any derivative software or any other software program based upon the Software v use any computer ...

Страница 30: ...EM OR TO OTHERS HAZARDOUS APPLICATIONS CUSTOMER ASSUMES ANY AND ALL RISKS INJURIES LOSSES CLAIMS AND ANY OTHER LIABILITIES ARISING OUT OF THE USE OF THE SOFTWARE IN ANY HAZARDOUS APPLICATIONS 3 4 Limitation of Liability a TOTAL LIABILITY NOTWITHSTANDING ANYTHING ELSE HEREIN ALL LIABILITY OF LICENSOR AND ITS SUPPLIERS UNDER THIS AGREEMENT SHALL BE LIMITED TO THE AMOUNT PAID BY CUSTOMER FOR THE RELE...

Страница 31: ...ensor within thirty 30 days of Licensorʹs written request 5 0 TERM AND TERMINATION 5 1 Term Subject to Section 5 2 below this Agreement will take effect on the Effective Date and will remain in force until terminated in accordance with this Agreement 5 2 Termination Events This Agreement may be terminated immediately upon written notice by either party under any of the following conditions a If th...

Страница 32: ...by and construed under the laws of the State of California and the United States as applied to agreements entered into and to be performed entirely within California without regard to conflicts of laws provisions thereof and the parties expressly exclude the application of the United Nations Convention on Contracts for the International Sales of Goods and the Uniform Computer Information Transacti...

Страница 33: ...S AND WARRANTIES INCLUDING WITHOUT LIMITATION ANY IMPLIED WARRANTY OF MERCHANTABILITY FITNESS FOR A PARTICULAR PURPOSE NONINFRINGEMENT OR ARISING FROM A COURSE OF DEALING USAGE OR TRADE PRACTICE ARE HEREBY EXCLUDED TO THE EXTENT ALLOWED BY APPLICABLE LAW IN NO EVENT WILL XIRRUS OR ITS SUPPLIERS BE LIABLE FOR ANY LOST REVENUE PROFIT OR DATA OR FOR SPECIAL INDIRECT CONSEQUENTIAL INCIDENTAL OR PUNITI...

Страница 34: ...export re export or import Equipment This Agreement shall be governed by and construed in accordance with the laws of the State of California United States of America as if performed wholly within the state and without giving effect to the principles of conflict of law If any portion hereof is found to be void or unenforceable the remaining provisions of this Warranty shall remain in full force an...

Страница 35: ... 2101 Corporate Center Drive Thousand Oaks CA 91320 USA To learn more visit xirrus com or email info xirrus com 2012 Xirrus Inc All Right Reserved This Xirrus logo is a registered trademark of Xirrus Inc All other trademarks are the property of their respective owners Content subject to change without notice ...

Отзывы: