XD2-230 Two-Radio Access Points

3

Install Mounting Hardware 

3A—Ceiling Mount 

We recommend use of the supplied AP mounting plate, which offers a more secure mount and ease of dismount. 

1.

Remove the mounting plate from the back of the AP (push it against the AP and twist it to the left). Use the 
holes on the mounting plate to mark the placement of at least two user-supplied screws to install in the ceiling. 

If not using the mounting plate, mark the locations for the two mounting screws on the ceiling—the centers are 
3.5” (8.9 cm) apart. 

2.

Drill and prepare holes for the screws as appropriate. 

3.

Cut an access hole for the cable(s) in the ceiling and draw enough cable through to attach to the AP after it is 
installed.

4.

If using the mounting plate, align it over the prepared holes. Secure the plate with the screws. Do not over-
tighten.

If not using the mounting plate, install two screws at the marked locations so that they protrude 1/8” (.3 cm) 
between the mounting surface and the head of the screw.

5.

Proceed to “Connect Cables and Install AP” on page 4.

NOTE: The AP must not be disassembled! If not using the mounting plate, do not remove the back of the AP to tighten the 
screws after mounting to ceiling.

3B—Ceiling Grid Mount with Mounting Plate

1.

Remove the mounting plate from the back of the AP (push it against the 
AP and twist it to the left). For T-Bar clips, use two of the four holes on 
the AP mounting plate to mark the placement of two T-Bar clips on the 
metal ceiling support grid. 

Twist the two supplied T-Bar clips onto the metal ceiling grid at the 
marked locations and tighten the screw posts to 10-12 lbf.ft (1.38-1.66 kgf.m). Do not over- tighten the screw 
posts. 

2.

Cut an access hole in the ceiling tile and draw the cable(s) through. 

3.

Align the AP mounting plate over the screw posts of the T-Bar  clips and secure it to the two posts using the 
nuts provided. Tighten the nuts to 10-12 lbf.ft (1.38-1.66 kgf.m), but do not over tighten. 

4.

Proceed to “Connect Cables and Install AP” on page 4.

3A—Ceiling Mount

3B—Ceiling Grid Mount with Mounting Plate

3C—Wall Mount with Bracket

3

Содержание XD2-230

Страница 1: ...posed to lightning strikes or possible crossover from high voltage lines AP PoE injectors and switches must be installed and used indoors The total Cat 5e or Cat 6 cable length from the switch to the AP must be no more than 100 m including all cable segments Power See the matrix below to select a compatible PoE switch or Xirrus supplied injector for your AP XD2 models require 802 3at If using an i...

Страница 2: ...d T Bar clips for 15 16 ceiling grid For a slotted ceiling grid T slot bolts are available for attaching the mounting plate to slots in the grid Wall Mount use a Wall Mount Accessory Kit XE 500 WALL which contains a mounting plate wall mount bracket and three screws 1 4 Plastite Choose a Suitable Location Choose an indoor location that is central to your users that is away from heat sources To ens...

Страница 3: ...between the mounting surface and the head of the screw 5 Proceed to Connect Cables and Install AP on page 4 NOTE The AP must not be disassembled If not using the mounting plate do not remove the back of the AP to tighten the screws after mounting to ceiling 3B Ceiling Grid Mount with Mounting Plate 1 Remove the mounting plate from the back of the AP push it against the AP and twist it to the left ...

Страница 4: ...y kit Other screws that seem equivalent in size may damage the mounting plate 2 Use the three screws provided in the accessory kit to attach the wall mount bracket to the AP mounting plate 3 Use the Wall Mounting Bracket as a template and mark the locations on the wall for the mounting holes The bracket must be secured to the wall in 3 places When marking the holes make sure the mounting plate is ...

Страница 5: ...detects and provisions new Xirrus devices deployed in your network via a similar provisioning approach Set up the SSH Users page in the Discovery section and create and configure a default profile for newly added APs After discovery these new devices automatically receive the configuration defined in your default profile If you are not using XMS see the Xirrus Wireless AP User s Guide to configure...

Страница 6: ...f the battery is replaced by an incorrect type Dispose of used batteries according to the battery manufacturer s instructions NOTE Power over Ethernet must be supplied by a UL listed I T E product 7 1 800 947 7871 Toll Free in the US 1 805 262 1600 Sales 1 805 262 1601 Fax 2101 Corporate Center Drive Thousand Oaks CA 91320 USA To learn more visit xirrus com or email info xirrus com 201 Xirrus Inc ...

Страница 7: ...he interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help FCC Caution Any changes or modifications not expressly approved by the...

Страница 8: ...sceptible d en compromettre le fonctionnement IMPORTANT NOTE IC Radiation Exposure Statement This equipment complies with IC RSS 102 radiation exposure limits set forth for an uncontrolled environment This equipment should be installed and operated with minimum distance 20 cm between the radiator your body Cet équipement est conforme aux limites d exposition aux rayonnements IC établies pour un en...

Отзывы: