Page
13
heat deflection temperature (HDT) of the material, you
can use it as a reference too. If you set the temperature
too high, your model may be irreparably damaged, as
your model may be deformed by the residual stresses
created during 3D printing. If you do not receive any
recommendation from the material manufacturer, test
the materials before dyeing them for the first time. To do
this, you can print a reference bar, and test it for
deformation in the dyeing bath.
Placing 3D parts
Use protective equipment (gown, goggles and gloves)
when loading the parts to avoid scalding and irritation.
Before loading the parts, switch off the
Vortex EZ
, open
the lid and lift the basket out of the basin. Place the basket
on the stand on top of the device frame.
Open the lid of the basket and carefully place the parts in
the basket. Close the lid of the basket. Carefully lower the
basket back into the tank. Close the lid, and turn on the
power of the
Vortex EZ
.
Removing 3D parts
Attention: When removing objects during the
dyeing process, it is essential to wear protective
equipment (gown, goggles and gloves). Before
opening the lid, the
Vortex EZ
should be
switched off.
Caution: Hot steam may escape when opening
the lid.
The duration of the dyeing process is strongly dependent
on the geometry of the part, the model material, the
amount of dye and the bath temperature. The model