Application

 

This hammer should be applied to breaking concrete, chipping off concrete, grooving, bar cutting, and 

driving piles in installation of piping and wiring, unitary facility installation, machinery installation water 
supply, and drainage work, interior jobs, harbor facilities and other civil engineering work etc..

 

 

Contents

 

1. Machine information

 

2. Safety instruction

 

3. Assembly

 

4. Operation

 

5. Maintenance

 

                                                                                                                                                                                                                 

 

Technical specifications

 

Machine Type 

   

XP-45HS 

Voltage 

AC 230V 

Frequency 

50Hz 

Input power 

1050W 

Impact rate 

3100/min 

Weight 

7.54kg 

Impact energy 

 

12J 

Bit lock style 

17mm hexagon flat shank lock system 

Sound pressure values (in 
accordance with 2000/14/EC) 

88dB(A) 

Guaranteed Sound power values 
(in accordance with 2000/14/EC) 

105dB(A) 

Vibration 

   

Main handle: 

a

h,Cheq

 :    

16.40

 

m/s

2

   

K=1.5m/s

Auxiliary

 handle: 

a

h,Cheq

15.20m/s

2   

K=1.5m/s

2

 

Standard accessories 

Hexagon bar wrench 5mm(for M6) 

1 piece 

grease tank cover wrench 

1 piece 

One box of grease 

 

30g (one box)

   

 

Bull point chisel(17*280mm) 

1 piece 

flat chisel(17*280mm) 

1 piece 

Carbon brush(6*10*14mm)  

2 pieces 

 

 

 

1. Machine information 

 

Содержание XP-45HS

Страница 1: ...the machine works and how it should be operated Maintain the machine in accordance with the instructions and make certain that the machine work correctly please store this instriation and other enclos...

Страница 2: ...ine Type XP 45HS Voltage AC 230V Frequency 50Hz Input power 1050W Impact rate 3100 min Weight 7 54kg Impact energy 12J Bit lock style 17mm hexagon flat shank lock system Sound pressure values in accor...

Страница 3: ...ttachments used may present risk of injury 1 Point chisel Hexagon size17 280 length Unit mm 2 Flat chisel Hexagon size17 280 length Unit mm 3 Big flat chisel Hexagon size17 280 length 50Cutting width...

Страница 4: ...in case of nonobservance of the instruction in this manual Indicate electrical shock hazard Immediately unplug the plug from the main electricity in the case that the cord gets damage and during main...

Страница 5: ...ic shock if your body is earthed or grounded c Do not expose power tools to rain or wet conditions Water entering a power tool will increase the risk of electric shock d Do not abuse the cord Never us...

Страница 6: ...ng power tools Such preventive safety measures reduce the risk of starting the power tool accidentally d Store idle power tools out of the reach of children and do not allow persons unfamiliar with th...

Страница 7: ...out in case 10 When chipping into walls floors or wherever live electrical wire may be encountered DON T TOUCH ANY METAL PARTS OF THE TOOL Hold the tool by the insulated grasping surface to prevent e...

Страница 8: ...ition 2 to pull out the bit follow the install procedure in reverse Prior to operation 1 Power source Ensure that the power source to be utilized conforms to the power requirements which specified on...

Страница 9: ...idle time this demolition hammer should be kept running for above 5 minutes to warm up How to replace grease This demolition hammer is full of air tight structure to protect against dust and to preve...

Страница 10: ...ne please avoid any damage to the winding or any water and oil to wet it 5 Carbon brush replacements 5 1 Carbon brushes are consumable parts when it becomes worn or limit worn it can cause motor troub...

Страница 11: ...validity Machine Description Demolition Hammer Machine Type XP 45HS Applicable EC Directive EC Machinery Directive 98 37 EC EC Low Voltage Directive 2006 95 EC EC Directive of Electromagnetic Compabi...

Страница 12: ......

Страница 13: ......

Отзывы: