V5 series inverter
97
2
2
2
2.... Communication
Communication
Communication
Communication address
address
address
address
:
00H
:
broadcast for all the inverters
(
broadcast
)
01H
:
communicate with the inverter addressed 01
0FH
:
communicate with the inverter addressed 15
10H
:
communicate with the inverter addressed 16
By parity of reasoning……….
,
max can reach 254
(
FEH
)
3
3
3
3.... Function
Function
Function
Function code
code
code
code and
and
and
and D
D
D
Data
ata
ata
ata
:
03H
:
Read data from registers
,
can read several registers with the numbers less than 31 and only can read the data in the
same group every time.
06H: Write data into the register.
08H: Diagnosis
10H: write several data to register
(
1
)
Function code 03H
:
read
register
For example
:
Read data from address2104H
(
Output current
):
RTU Mode
:
(
2
)
Function code 06H
:
Write to register
For example
:
01H
,
write function code P0.02=50.00HZ
.
RTU Mode
:
(
3
)
Command mode
:
08H Diagnosis
This command is used for testing that if the communication between the client device (master) and inverter(slave) is
normal.Inverter will sent the data to control device.
RTU mode
:
Request mode
Response mode
Address
01H
Address
01H
Function code
03H
Function code
03H
Register address
21H
Byte No.
02H
04H
Register No.
00H
Dada
00H
01H
00H
CRC CHECK Low
CFH
CRC CHECK Low
B8H
CRC CHECK High
F7H
CRC CHECK High
44H
Request mode
Response mode
Address
01H
Address
01H
Function code
06H
Function code
06H
Register address
00H
Register address
00H
02H
02H
Data
13H
Data
13H
88H
88H
CRC CHECK Low
25H
CRC CHECK Low
25H
CRC CHECK High
5CH
CRC CHECK High
5CH
Request mode
Response mode
Address
01H
Address
01H
Function code
08H
Function code
08H