background image

 

24 

 

TG series HMI 

3-1 Features 

Xinje  TG  series  HMI  have  high  quality  display:  16  million  true  color  TFT-LCD,  support 

BMP  and  JPG  format,  have  rich  3D  photo  gallery,  has  the  flexible  components  choice 

space, user-defined animation, convenient mode setting switch, precise touch calibration 

function,  data  acquisition  save  function,  curve  shows,  and  other  forms  of  data 

management ways, offers two USB interfaces, perform high speed data download, high 

speed  loading  and  high-speed  operation,  can  communication  with  several  PLC 

simultaneously, support Ethernet communication. 

 

3-1-1 Product features 

 

Display 

    16 million true colors TFT-LCD, support BMP and JPG format, better color and 

display; 

    Precise touch calibration function; 

    128MB  memory,  perform  high  speed  data  download,  high  speed  loading  and 

high-speed operation 

    Memory capacity increase substantially; 

    Support multi-language: Chinese, English, Japanese, Korean, German, French, 

Arabic, etc. The fonts support any size, artistic effect, bold, italic, etc.     

  Rich images of material, screen operation   

 

Control 

    Switch control, dynamic monitor and display data, bar map, real time trend map, 

time trend map, XY trend map, discrete/continue column map, real time alarm, 

history alarm record

… 

    User-defined data collection and saving function 

    Set user authority, 9 levels password protection 

    Simulate online/offline, upload/download data, configuration function 

    Powerful C function block 

    USB port inside, connect flash disk to copy data, speed up to 480Mbps 

    Special USB-B port for data download, make the data transfer faster 

    User-defined animation design 

    Contain all function of TH series 

 

Communication 

    Two ports communication independently, can connect two different devices at the 

same time 

    Add Ethernet interface communication 

    Drive the panel printer directly, economical and flexible 

    Support free format communication, user edits the driver program 

Содержание TG Series

Страница 1: ...TP TH TG series HMI manual Hardware WUXI XINJE ELECTRIC CO LTD Data No HC 01 20120105 2C6 ...

Страница 2: ......

Страница 3: ...0 2 1 2 Model naming rule 11 2 1 3 Model form 11 2 2 General specifications 12 2 3 Hardware 14 2 3 1 Hardware structure 14 2 3 2 Port introduction 14 2 4 Dimensions and installation 20 2 4 1 Product dimensions 20 2 4 2 Installation and using environment 22 3 TG SERIES HMI 24 3 1 Features 24 3 1 1 Product features 24 3 1 2 Module naming rule 25 3 1 3 Product models 25 3 2 General specifications 26 ...

Страница 4: ......

Страница 5: ...German French Arabic etc The fonts support any size artistic effect bold italic etc Large program capacity support more program screens and data Control Dynamic data displaying and monitoring bar map real time historical trend map discrete continuous histogram switching control Real time historical alarm records Sample and save the data at certain time or conditions Nine levels password protection...

Страница 6: ...emperature 25 running for 24 hours Language Chinese English Japanese Korean German French Arabic Character Any font and size Memory Capacity 2MB 4MB Electric specifications Item TP460 L TP760 T Electric Input voltage DC24V voltage range DC22V DC26V Consumption current 200mA 280mA Allowable momentary power failure Below 10ms Actual power failure 1s Withstand voltage AC1000V 10mA less than 1 minute ...

Страница 7: ...on mm 165 2 113 4 182 4 134 4 Ports PLC port Support RS232 RS485 RS422 Download port Support RS232 RS485 1 3 Hardware 1 3 1 Hardware structure The hardware structure of TP series touch screen includes front and back side Take TP460 L as an example to explain the structure 1 3 2 Port introduction Xinje TP series HMI have two communication ports Download port and PLC port below is the feature and fu...

Страница 8: ...used terminal 1 Download function When you use download function of TP series please use Xinje special download cable Before user download a program please make sure your PC has installed multiport serial card or USB RS232 convertor and connect cable correctly click button in Touchwin software then you could download data successfully below are the pin definitions PC serial Port COM Download Port ...

Страница 9: ...rt of TP series not only has the download function but also has the powerful communication function When use the communication function of download port please shorted the pin 5 and pin 6 select the corresponding communication equipment in software settings Download port communication mode transformation Select communication device of download port Receive data Send data Printer PLC TP Series HMI ...

Страница 10: ...unication port Pin Definition Description 1 TD RS422 send 2 RXD RS232 receive 3 TXD RS232 send 4 A RS485 5 GND Signal ground 6 TD RS422 send 7 B RS485 8 RDD RS422 receive 9 RDD RS422 receive 1 Communicate with PLC TP series HMI can communicate with most of popular PLCs Please select correct PLC port device and communication parameters Data transfer TP Series PLC com port SIEMENS PLC Panasonic PLC ...

Страница 11: ...otocol 3 Communicate with meters About the communication between TP and meters users can select user defined protocol or Modbus protocol 1 4 Dimension and installation 1 4 1 Product dimensions TP460 L Unit mm 0 0 0 5 0 0 0 5 40 6 165 0 113 0 163 2 45 1 111 4 121 4 173 2 PLC com port TP series Mitsubishi FR series inverter Inovance MD series inverter Bosch Rexroth FE series inverter ...

Страница 12: ...ight side of the TP when installing Install steps 1 Refer to the dimension in the former chapter to open a rectangle mounting hole in the control cabinet 2 Add airproof circles in the airproof slot when installing 3 Insert the bottom of TP into the mounting hole of control cabinet 4 Insert the install rack into the fix hole of TP then tighten the screw 5 Connect TP and PLC with communication cable...

Страница 13: ...h screen use DC 24V power supply only The permitted voltage range is 20V 26V The connection is as below 24V 0 V DC DC 0 V 24V Terminal type Pin type Besides if connect high voltage or AC power supply with TP the TP may be damaged and cause electric shock to human body NOTE if use the DC 24V output of PLC to drive the TP make sure the PLC has enough current to drive the TP ...

Страница 14: ...se Korean Define the font as you like support underline italic bold shadow and other art words Large picture library with preloading mode no delay for screen motion Control Switch control dynamic monitor and display data bar map real time trend map time trend map XY trend map discrete continue column map real time alarm history alarm record User defined data collection and saving function Set user...

Страница 15: ... Increase a com port RS232 base on the TH465 MT UT TH765 NT3 NU3 Increase a com port RS485 base on TH765 NT NU 2 1 3 Model form TH series include TH465 TH765 TH865 THA62 and THA65 1 About the hardware configuration of each model please refer to below TH series HMI configuration form 2 The difference between TH765 N and TH765 M Use different LCD module but the function parameters and specifications...

Страница 16: ...1 800 480 128M B 232 485 232 485 42 2 THA62 UT 2 THA65 THA65 MT 10 4 800 600 128M B 232 485 232 485 42 2 THA65 UT 2 TH series add two kind of power off retentive registers PHW 520 thousand registers and PRW 1 thousand registers so if user need the PHW register user should mark it and TH465 doesn t have PHW it only has PRW 2 2 General specifications HMI specifications Item TH465 TH765 TH865 THA62 T...

Страница 17: ...d voltage AC1000V 10mA less than 1 minute signal and ground Insulated impedance DC500V above 10MΩ signal and ground Environment Operation temperature 0 50 Reserve temperature 20 60 Humidity 10 RH 90 RH no condensation Withstand oscillation 10 25Hz X Y Z each direction 30 minutes 2G Anti jammin g Voltage noise 1500Vp p pulse 1us 1 minute Surrounding air No corrosive gas Protection construction IP65...

Страница 18: ...ow is the back side of TH series HMI 2 3 2 Port introduction TH series HMI port Outline Name Function 1 2 3 4 1 2 3 4 DIP switch Force download touch area adjustment Download COM 1 RS232 RS485 communication PLC COM 2 RS232 RS485 RS422 communication USB A Connect to U disk USB B Connect USB cable to download upload program Nameplate Power supply COM 1 COM 2 USB B DIP switch USB A ...

Страница 19: ...ownload to update the system Steps 1 Cut off the power of TH turn ON DIP switch 2 2 Power on TH connect the download cable to PC to download the program 3 Turn OFF DIP switch 2 after finishing the download repower on the TH 1 2 3 4 ON OFF 2 Communication interface The COM1 and COM2 port of TH series has below function Communication function Connect to PLC printer inverter meter etc used as communi...

Страница 20: ...DD RS422 receive The COM1 pins definition of TH765 NT3 NU3 series Pin Name Description 1 A RS485 signal 2 RXD RS232 receive 3 TXD RS232 send 4 A RS485 signal 5 GND Signal ground 6 B RS485 7 B RS485 8 NC Unused terminal 9 NC Unused terminal The communication interface of TH series HMI has powerful communication function Receive data Send data Inverter PLC TH Series HMI COM port Other devices ...

Страница 21: ...C port COM2 device and communication parameters COM2 device selection COM2 communication parameter setting Select the correct download port COM1 device and communication parameters COM1 device selection COM1 communication parameter setting Data transfer TH series COM port SIEMENS PLC Panasonic PLC Other PLCs ...

Страница 22: ... series USB A port has below functions accord with USB2 0 Backup management data export import the speed can up to 480 Mbps USB A port definition Connect to USB flash drive 4 USB B port TH has one USB B port accord with USB2 0 located at the back side of TH the functions are shown as below Pin Name Description 1 5V 5V voltage signal 2 DATA Data signal 3 DATA Data signal 4 5V 5V voltage signal TH f...

Страница 23: ... USB cables 2 Please install USB driver before using Download the driver from www xinje com 3 Connect TH with PC open Touchwin software click or to download the program Pin Name Description 1 5V 5V voltage signal 2 DATA Data signal 3 DATA Data signal 4 GND Ground signal TH back side PC USB cable ...

Страница 24: ...t mm 24V 0V FG 1 2 3 4 92 0 142 0 41 8 152 0 102 0 144 0 94 0 PLC 1 2 3 4 0 5 0 0 0 5 0 0 TH765 M TH765 N Unit mm 1 2 3 4 24V 0V FG 1 2 3 4 COM1 COM2 MODE TW760T S N N20081028028 THINGET Xinje Electronic Co Ltd 136 5 190 0 43 9 7 0 204 0 150 5 138 5 192 0 0 0 0 5 0 0 0 5 ...

Страница 25: ...Unit mm 1 2 3 4 1 2 3 4 Download PLC 24V 0V FG 224 4 170 8 38 0 45 5 155 8 209 4 0 5 0 0 0 5 0 0 211 4 157 8 THA62 Unit mm Download PLC 24V 0V FG 1 2 3 4 272 2 191 7 51 2 258 2 177 7 260 2 179 7 1 0 0 0 1 0 0 0 ...

Страница 26: ... the up down and 5cm on the left right side of the TH when installing Install steps 1 Refer to the dimension in the former chapter to open a rectangle mounting hole in the control cabinet 2 Add airproof circles in the airproof slot when installing 3 Insert the bottom of TH into the mounting hole of control cabinet 4 Insert the install rack into the fix hole of TH then tighten the screw 5 Connect T...

Страница 27: ...ure inside TH Power supply requirements TH series touch screen use DC 24V power supply only The permitted voltage range is 20V 28V The connection is as below Besides if connect high voltage or AC power supply with TH the TH may be damaged and cause electric shock to human body If use the DC 24V output of PLC makes sure the PLC has enough current to drive the TH 24V 0 V DC ...

Страница 28: ... substantially Support multi language Chinese English Japanese Korean German French Arabic etc The fonts support any size artistic effect bold italic etc Rich images of material screen operation Control Switch control dynamic monitor and display data bar map real time trend map time trend map XY trend map discrete continue column map real time alarm history alarm record User defined data collectio...

Страница 29: ...pact type of TG765 MT it has USB B port one RS232 port with clock 3 1 3 Product models Model LCD size Display Notes TG765 MT UT ET TG765 XT TG765 XT C 7 TFT LCD MT USB B download port UT USB B download port USB A U disk port ET USB B download port USB A U disk port Ethernet port XT compact type of TG765 MT it has USB B port one RS232 port without clock XT C compact type of TG765 MT it has USB B po...

Страница 30: ...n French Arabic Character Any font and size Memory Capacity 128MB Electric specifications Item TG765 TG865 TGA62 TGC65 Electric Input voltage DC24V Range DC22V DC26V Consumpt ion current 200mA 230mA 250mA 710mA Allowable momentar y power failure Below 10ms Actual power failure 1s Withstand voltage AC1000V 10mA less than 1 minute signal and ground Insulated impedanc e DC500V above 10MΩ signal and g...

Страница 31: ...1 2 410 0 270 0 65 0 Mounting dimension mm 192 0 138 5 211 4 157 8 260 2 179 7 399 0 259 0 Interface PLC port RS232 RS485 RS422 TG765 XT TG765 XT C only support RS232 Download port RS232 RS485 TG765 XT and TG765 XT C don t have this port Ethernet port RJ45 Only for ET series USB1 USB A accord with USB2 0 USB flash drive port USB2 USB B accord with USB2 0 USB download port 3 3 Hardware 3 3 1 Hardwa...

Страница 32: ...nload touch area adjustment Download Download port RS232 RS485 PLC PLC port RS232 RS485 RS422 USB A Connect to USB flash drive USB B Connect USB cable to download upload program Ethernet port Support TBOX Siemens S7 1200 and other devices which support Modbus TCP protocol Nameplate Power supply Download port PLC port USB B DIP switch USB A RJ45 ...

Страница 33: ... Cut off the power of TG turn ON DIP switch 2 2 Power on TG connect the download cable to PC to download the program 3 Turn OFF DIP switch 2 after finishing the download repower on the TG 1 2 3 4 ON OFF 2 Communication interface The Pins definition of download port Pin Name Description 1 NC Unused terminal 2 RXD RS232 receive 3 TXD RS232 send 4 A RS485 signal 5 GND Signal ground 6 NC Unused termin...

Страница 34: ...rd with USB2 0 of TG series HMI has below function Backup management data export import the speed can up to 480 Mbps USB A port definition 4 USB B port TG has one USB B port accord with USB2 0 located at the back side of TG the functions are shown as below To download the data the speed can up to 480Mbps USB B port definition Pin Name Description 1 5V 5V voltage signal 2 DATA Data signal 3 DATA Da...

Страница 35: ...pen Touchwin software click or to download the program 5 RJ45 port The pins definition of RJ45 port 1 8 Pin Color Name Explanation 1 Orange white TXD Send 2 Orange TXD Send 3 Green white RXD Receive 4 Blue 5 Blue white 6 Green RXD Receive 7 Brown white 8 Brown 3 4 Dimensions and installation 3 4 1 Product dimensions TG765 MT UT ET Unit mm ...

Страница 36: ...21028028 THINGET Xinje Electronic Co Ltd 43 4 6 6 200 4 146 9 136 5 190 0 138 5 192 0 PWR TG765 XT TG765 XT C Unit mm 1 2 3 4 24V 0V FG 1 2 3 4 MODE TG760T XT S N N20121028028 TouchWin Xinje Electric Co Ltd 43 4 6 6 200 4 146 9 136 5 190 0 PWR PLC 1 3 8 5 1 9 2 0 ...

Страница 37: ...33 TG865 MT UT ET Unit mm 211 4 157 8 1 2 3 4 1 2 3 4 Download PLC 24V 0V FG 155 8 209 4 224 4 170 8 38 0 45 5 TGA62 MT ET Unit mm Download PLC 24V 0V FG 1 2 3 4 272 2 191 7 51 2 258 2 177 7 260 2 179 7 ...

Страница 38: ...ounting rack to fix the TG with control cabinet In order to avoid TG temperature too high after long time working please keep 10cm space on the up down and 5cm on the left right side of the TG when installing Install steps 1 Refer to the dimension in the former chapter to open a rectangle mounting hole in the control cabinet 2 Add airproof circles in the airproof slot when installing 3 Insert the ...

Страница 39: ...ouch screen indoor Do not use TG in below environment Inflammable gas steam dust fast vary temperature high humidity it may cause moisture inside TG Power supply requirements TG series touch screen use DC 24V power supply only The permitted voltage range is 20V 26V The connection is as below Besides if connect high voltage or AC power supply with TG the TG may be damaged and cause electric shock t...

Страница 40: ......

Страница 41: ...WUXI XINJE ELECTRIC CO LTD 4th Floor Building 7th No 100 Dicui Rd Wuxi China Tel 86 0510 85134139 Fax 86 0510 85111290 www xinje com Email cheerfiona gmail com ...

Отзывы: