37
Line driver pulse wiring method
PLC, CNC, SCM servo driver
HP-
HP+
GND
120
Ω
2K
Ω
2K
Ω
HD-
HD+ 2K
Ω
2K
Ω
10K
Ω
10K
Ω
10K
Ω
10K
Ω
GND
Note:
In order to resist interference, twisted-pair shielding wire must be used.
Note:
(1) The power supply voltage range of P- / P+ 24V and D- / D+ 24V is 18V ~ 25V. The power
supply voltage range of P- / P+ 5V and D- / D+ 5V is 3.3V ~ 5V. If it is lower than 18V / 3.3V, there
may be abnormal pulse and direction.
(2) Servo pulse input port is ON for 10mA.
(3) If the controller is Xinje PLC, the rated current of the pulse output port is 50mA. According to
this data, it can be judged that one pulse theoretically can drive at most five servos. It is recommended
not to exceed 3.
3.2.2 SI input signal
Please use a relay or an open collector transistor circuit to connect. When using relay connection,
please select the relay for small current. If the relay is not small current, it will cause bad contact.
Type
Input terminal
Function
Digital input
SI1~SI10
Multifunctional input signal terminal
Defaulted assignment of input terminals
Terminal
SI1
SI2
SI3
SI4
SI5~SI10
Function
S-ON/
enable
ALM-RST/alarm reset
P-OT/forward run
prohibition
N-OT/reverse run
prohibition
Not
distribute
Open collector (power supply is 24V)
Relay type (power supply is 24V)
Upper device servo driver
SI
+24V
+
COM2
Y2
0
V
+24
V
R=3.3K
Ω
Upper device servo driver
R=3.3K
Ω
+24
V
0
V
Y2
COM2
+
+24V
SI
Note: SI10 terminal is high-speed input port, and SI1-SI9 are low-speed input ports.
3.2.3 SO output signal
Type
Output terminal
Function
Optocoupler output
SO1~SO8
Multifunctional output terminal
Note:
(1) It is suggested
to
add
the
differential
isolation board of
Xinje;
(2) CW/CCW pulse
input frequency is
2M at most, and
AB
phase
pulse
frequency is 2M at
most.
Содержание DS5F Series
Страница 1: ...DS5F series servo driver User manual WUXI XINJE ELECTRIC CO LTD Data No SC5 02 20200217 2 3 ...
Страница 2: ......
Страница 41: ...39 3 2 5 Encoder feedback output signal Servo driver differential to collector upper device ...
Страница 124: ...122 2 select jog setting or manual setting to configure the inertia estimation trip 3 Set the auto tuning interface ...
Страница 202: ...200 Appendix 9 Torque speed characteristic curve ...
Страница 203: ...201 ...
Страница 204: ...202 ...