13
Installation Near a
Heating Unit
Minimize heat radiated from the heating unit as well as any temperature
rise caused by natural convection so the temperature around the servo
drives does not exceed 50°C.
Installation Near a Source
of Vibration
Install a vibration isolator beneath the servo drive to avoid subjecting it to
vibration.
Installation at a Site
Exposed to Corrosive Gas
Corrosive gas does not have an immediate effect on the servo drives, but
will eventually cause electronic components and terminals to malfunction.
Take appropriate action to avoid corrosive gas.
Other Situations
Do not install the servo drive in hot and humid locations or locations
subject to excessive dust or iron powder in the air.
2-2-3
.
Orientation
Install the servo drive perpendicular to the wall as shown in the figure. The servo drive must be
oriented this way because it is designed to be cooled by natural convection or by a cooling fan.
2-2-4
.
Installation
Follow the procedure below to install multiple servo drives side by side in a control panel.