DP-708/DP-5022 series stepper driver
10
Table 1 driver parameters
Table 2 Serial port parameters
Function
Default Setting
Setting Range
P0-04.0
Baud Rate
6
0~9
0: 300
1: 600
2: 1200
3: 2400
4: 4800
5: 9600
6: 19200
7: 38400
8: 57600
9: 115200
P0-04.1
Data Bit
0
0: 8
P0-04.2
Stop Bit
2
0: 2 Bit
2: 1Bit
P0-04.3
Parity Bit
2
0~2
0: None
1: Odd
2: Even
The steps to change the parameters:
The parameter setting is used to change the parameters. Check the permitted range of
the parameters in the above table before changing the data.
This example shows how to change parameter P0-02 from 8 to 16.
1. Press the STATUS/ESC key to enter parameters setting mode and then press the
ENTER key to enter.
2. At this time ,the left second LED is blinking ,and press ENTER key to confirm, the
right two LEDs are blinking, press INC key, DEC key or ENTER key to select NO. 2
P0-
Name
Unit
Default
setting
Setting range
Reference
00
Phase-current (virtual value
)
0.1A 10
0~70
01
Half-current enable
0
0~1
0: Half-current
1: Full-current
02
Pulse number per circle
1600
200~65535
03
Modbus station NO.
1
1~255
04
Parameters of serial port
2206
0~2209
Refer to table 2
05
Internal / External Pulse
Selection
0
0~1
0: External Pulses
1: Internal pulses