6

/

10

7th. Installation method

Open installation holes on the panel where the sensor needs to be installed, and place the nuts in the upper and lower

fixing holes of the sensor or in the front and rear fixing holes to tighten to achieve up and down or front and rear fixing.

8th. Instructions method

When the sensor is working normally, put the liquid pipe into the pipe clamp wire groove. The instruction light is on

and the output is high, indicating that there is liquid passing through the current position of the tube. The indicator light is
off and the output is low, indicating that no liquid is passing through the current position of the tube .

9th. Sensitivity setting steps

The sensitivity of the product shall be calibrated in strict accordance with the standard before delivery; However, in the

actual use process, it may be necessary to fine tune the accuracy of sensitivity according to the on-site environment to achieve a
better experience effect.
1. Connect the sensor circuit as required.
2. Align the liquid level in the liquid pipe with the center of the sensor.
3. Turn on the power supply to power up the sensor.
4. After the mark line of the sensor (sensitivity calibration line) and the sensor gnd wire are shorted for about 1 second, the
mark line is converted from high level to low level, and the LED lamp of the sensor flashes to indicate that the sensor enters the
calibration state. After entering the calibration state, the mark line and the gnd wire are separated, and the calibration is
completed successfully when the LED lamp is always on.
Precautions: In normal use, the mark wire of the sensor(sensitivity calibration line) can only be suspended in the air and cannot
be connected to the positive or negative pole of the power supply.

It is recommended that the sensitivity calibration line be

connected to the negative pole (GND) through a switch. When setting the sensitivity, the switch should be closed, and it should
be disconnected in normal use.

In the picture above, there is no liquid in the
water pipe at the detection level, and the
indicator light does not light up

In the picture above, there is liquid in the water
pipe at the detection level, and the indicator
light is on

Содержание XKC-Y27B-D3-PUB

Страница 1: ...7B PUB content 1st Overview 2 2nd Scope of application 2 3rd Technical Parameters 2 4th Wiring diagram 3 4 1 Wiring diagram of XKC Y27B Dx V 3 4 2 Wiring diagram of XKC Y27B Dx NPN 4 5th Product selec...

Страница 2: ...liquid will be coupled to this static capacitance making the capacitance value of the sensor larger and the changed capacitance signal is then input to the control IC for signal conversion which will...

Страница 3: ...s models 4 1 Wiring diagram of XKC Y27B Dx V High and low level output drive small relay coil current 100mA working principle When the liquid is sensed the transistor will cut off and output a high le...

Страница 4: ...iao Street Baoan District Shenzhen 4 10 4 2 Wiring diagram of XKC Y27B Dx NPN NPN output drives small relays coil current 100mA working principle When the liquid is sensed the transistor is turned on...

Страница 5: ...he outer diameter of the clampable water pipe is 3mm 2 XKC Y27B D3 NPN NPN 3 XKC Y27B D4 V High and low level The outer diameter of the clampable water pipe is4mm 4 XKC Y27B D4 NPN NPN 5 XKC Y27B D6 V...

Страница 6: ...on site environment to achieve a better experience effect 1 Connect the sensor circuit as required 2 Align the liquid level in the liquid pipe with the center of the sensor 3 Turn on the power supply...

Страница 7: ...10 URL http www sz xkc com Address 11th Floor No 48 Xinyu Road Xinqiao Community Xinqiao Street Baoan District Shenzhen 7 10 10th Physical shape map XKC Y27B D3 XKC Y27B D4 XKC Y27B D6 XKC Y27B D8 XKC...

Страница 8: ...than 30mPaS it cannot be measured because a large amount of liquid adheres to the wall of the container 2 Note As the temperature increases the viscosity decreases and most high viscosity liquids are...

Страница 9: ...cking list do not match after the first unpacking of the product some or all of the components cannot be used normally after the first unpacking of the product surface scratches or other things that d...

Страница 10: ...activities and the company does not guarantee it and is not liable to customers or third parties 4 Due to product version upgrades or other reasons the contents of this manual may change Xingkechuang...

Отзывы: