xiX - Technical Manual Version 1.3
19
3.
Hardware Specification
3.1.
Power Supply
The xiX cameras are powered via flex cable from an external power supply 12-24V with power consumption up to 10W max
(without power needed for lens). Please read the chapter
3.8 xiX X2G2 Interface connector
and
3.9 xiX X4G2 Interface connector
regarding camera pinout. Breakout board can be used to power camera see
3.2.
General Specification
3.2.1.
Environment
Description
Symbol
Value
Optimal ambient temperature operation
T
opt
+10 to +25 °C
Ambient temperature operation
T
max
0 to +50 °C
Ambient temperature for storage and transportation
T
storage
-30 to +60 °C
Relative Humidity, non-condensing
RH
≤
80 %
table 3-1, environment
Housing temperature must not 65°C. The following parameters are not guaranteed if the camera is operated outside
the optimum range:
•
Dark current
•
Dynamic Range
•
Linearity
•
Acquisition and readout noise
•
S/N ratio, durability
Please refer to chapter:
3.2.2.
Firmware / Host driver / API features
Description
Value
Interpolation methods
SHT advanced
White balance coefficients ranges
0.0 to 3.9
Sharpness filter
-400 to 400 %
Gamma
0.3 to 1.0
Full color correction matrix (3+1)x3 coefficients ranges
-3.9 to 3.9
table 3-2, firmware / API features
More details on API/SDK features are available at