VCU1287 IBERT Getting Started Guide
36
UG1203 (v2016.4) December 15. 2016
Chapter 1:
VCU1287 IBERT Getting Started Guide
Viewing GTY Transceiver Operation
After completing step 10 above page x in
Setting Up the Vivado Design Suite, page 18
IBERT demonstration is configured and running. The status and test settings are displayed
on the Links tab in the Links window shown in
.
Review the line rate and RX bit error count. The line rate for all four GTY transceivers is
28.0 Gb/s (see MGT Link Status in
). Verify that the there are no bit errors.
In Case of RX Bit Errors
If there are initial bit errors after linking, or as a result of changing the TX or RX pattern, click
the respective
BERT Reset
button to zero the count.
If the MGT Link Status shows No Link for one or more transceivers:
• Make sure the blue elastomer seal is connected to the bottom of the Bulls Eye cable
and the cable is firmly connected and flush on the board.
• Increase the TX differential swing of the transceiver (to compensate for any loss due to
PCB process variation).
• Click the respective
TX Reset
button followed by
BERT Reset.
X-Ref Target - Figure 1-29
Figure 1-29:
Serial I/O Analyzer Links
X15565-121416