1-Gigabit Ethernet MAC v8.5 User Guide
www.xilinx.com
85
UG144 April 24, 2009
Using the Optional Management Interface
R
-- DISCONTINUED PRODUCT --
Accessing the Address Table
To write to a specific entry in the address table, you must first write the least significant 32-
bits of the address into the Address Table Configuration (Word 0) register. You then write
the most significant 16 bits together with the location in the table (bits 17–16) to the
Address Table Configuration (Word1) register with bit 23 (read not write) set to ‘0.’ This is
shown in
Figure 8-3
. Although it is shown in the figure, there is no requirement for the two
writes to be on adjacent cycles.
As shown in
Figure 8-4
, you must write to the Address Table Configuration register (Word
1) with the location set to the desired table entry and bit 23 set to ‘1’ to read from the
address table. On the next cycle the least significant word appears on the
hostrddata
bus. One cycle afterwards, the most significant 16-bits are output on the lower 16 bits of the
bus.
Figure 8-3:
Address Table Write Timing
hostclk
hostaddr[8:0]
hostaddr[9]
hostopcode[1]
hostmiimsel
BITS15..0 = ADDR[47:32]
hostwrdata[31:0]
0x188
0x18C
ADDR[31:0]
BITS17..16 = LOCATION
BIT23 = 0
BIT31
BIT0